Recommended fuel: Unleaded gasoline
Fuel tank volume: see specifications table.
CHECK THE OIL LEVEL
CHECK THE OIL LEVEL
Generstor is transported without the motor oil. Please don't start the engine
without filling the sufficient amount of motor oil.
1. Unscrew the oil dipstick and wipe it out with a clean cloth.
2. Insert the dipstick without screwing it in.
3. Check the oil level by a mark on the oil dipstick.
4. Add oil if its level is below the mark on the oil dipstick.
5. Screw on the dipstick.
Recommended engine oil: SAE 10W-30, SAE 10W-40.
Recommended engine oil grade: API Service SE type or higher.
Motor oil quantity: see specifications table.
Before starting the engine, make sure that the rated power of power consumers matches with the power of
generator. Do not exceed the nominal power of the generator. Do not connect any devices before you start
the engine!
Do not tilt the generator when adding engine oil. This could result in over filling and damage to the engine. The
generator can be used with the rated output load at standard atmospheric conditions.
IMPORTANT!
ATTENTION - DANGER!
In practice, there are different options for supplying electricity, and different rules for connecting
it. The decision on how to properly connect the equipment in each individual case must be made
by a certified electrician who performs the installation. The manufacturer is not responsible for
incorrect installation, and is not responsible for any material and physical damage that may result
from improper installation or operation of the equipment.
IMPORTANT!
IMPORTANT!
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal
(operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after
operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
ENGINE START
ENGINE START
IMPORTANT!
Do not change the controller settings in terms of the amount of
fuel or speed governor (this adjustment was made at the factory).
Otherwise, this may result in changes in the engine operation or
its failure.
In the power supply mode, the generator should operate no longer
than 1 minute in the range from nominal to maximum power.
Before starting the generator, connect the ground wire to the
ground terminal.
Please consult with a specialist before using the ground terminal.
Useful tip: If the engine stalls or does not start, turn the engine
switch to the "ON" position, and then pull the manual starter.
If the oil level indicator flickers for several seconds, add oil and
restart the engine.