6. First-time setup via the "Start-up Guide"

At each step, if defaulted to the correct selection, press
the [Down] button to continue to the next step. If the se-
lection needs to be changed, press OK and use the [Up]
and [Down] buttons until the correct selection is highlight-
ed. Press OK again, then press the [Down] button to con-
tinue to the next step.
1. Press OK to begin the Start-up Guide.
Start-up Guide
Welcome to the CUE Start-
up guide. Press OK to
continue
Welcome screen
2. Press OK to select the desired language.
Start-up Guide
Please select language:
English
Language
3. Select the "Imperial" unit type.
Start-up Guide
Please select the units used
for setup
Imperial
Units
Imperial units are, for example, psi, hp and gpm as opposed to
metric units like bar, kW and m
4. Select the SP pump family.
Start-up Guide
Please select the pump you
are running or select other
for unrestricted settings
SP, SPE
Pump type
10
1(1)
1(1)
3
/h.
1(1)
5. Select "Asynchronous motor" as the motor type.
Start-up Guide
Please select the motor of
the pump or select "skip
motor setup"
Asynchronous motor
Motor type
6. Enter the motor power found on the motor nameplate.
Start-up Guide
Enter Total Motor Power:
1.50 hp
Motor power
7. Enter a nominal voltage closest to the actual measured supply
voltage.
Start-up Guide
Enter Total Motor Voltage:
230 V
Motor voltage
The actual supply voltage must be within the voltage
range of the motor.
8. Enter the motor frequency and the maximum continuous current
(MCC).
Start-up Guide
Select Motor Frequency:
60Hz
Max Cont. Current (MCC):
5.1A
Motor frequency and MCC
The motor frequency is defaulted to 60 Hz. Press the [Down]
button to keep the default value.
As MCC, enter the SFA value found on the motor nameplate.