3.7.6 Configure Quick Settings

Under the Basic Setting > Quick Setting window (Figure 3-19) are several important fields you must
configure and/or verify. First, if the operator is using the Baicells CloudCore EPC, you must enter a
fixed Public Land Mobile Network (PLMN) and MME IP address:
PLMN = 314030
MME IP = 10.3.0.9 and 10.5.0.9
Do not change these settings except when connecting to a Local (private network) EPC or different
vendor's Evolved Packet Core (EPC). Second, you must enter the operator's planned settings for
Band, Bandwidth, EARFCN, Cell ID, PCI, TAC, etc. Some Quick Setting fields such as Duplex Mode
and Frequency will auto-fill based on the eNB hardware model. Make sure the Cloud EPC field is
set to ON when using the Baicells CloudCore. If you are testing the eNB in a lab environment, turn
the power down as low as it will go under the Power Modify field.
NOTE 1: If planning to use CBRS SAS, the SAS vendor will determine some of these
parameters. Refer to the
NOTE
2:
Nova430i does not
For a description of all the eNB Quick Setting fields, refer to the
Description
Option available when SNMP option is enabled:
SNMP Version
SNMP System Name
SNMP Port
Contact
Location
Community String
Source
Option available when SNMP option is enabled:
Trap Community String
Trap Server
SAS Deployment Guide
for more information.
support SFA = 0.
31
eNodeB Configuration
Guide.