Discharging And Earthing The Test Object - Baur PD-TaD 62 User Manual

Portable diagnostics system
Table of Contents

Advertisement

PD-TaD 62
14
D
ISCHARGING AND EARTH ING THE TEST OBJECT
On completion of cable testing or measurement the test object still carries a dangerous
voltage.
822-187-3
DANGER
Dangerous voltage in test object.
Danger of electric shock or risk of injury
 Before touching, discharge, earth and short-circuit: The test
object at the connection point and at the far end.
 You may touch the plant parts that were under voltage only if they
are visibly earthed and short-circuited.
 Connect the discharge and earth rod correctly to the station earth.
 Only use the discharge and earth rod if its surface is clean and dry.
 Hold the discharge and earth rod only at the handles!
 Observe the minimum discharge period in accordance with the
capacitance of the test object.

Discharging and earthing the test object

93 / 114