Full Illustration Of The Pd-Tad And System Components - Baur PD-TaD 62 User Manual

Portable diagnostics system
Table of Contents

Advertisement

Product information
3.2

Full illustration of the PD-TaD and system components

No.
Element
1
Laptop
2
PD-TaD 62
3
Power Box
4
VLF HV generator
5
HF filter
16 / 114
Function
The laptop with the BAUR software 4 installed on it forms the graphical
interface for controlling the PD diagnostics system and evaluating the
measurement results. The measurement results are displayed, analysed
and archived in the BAUR Software.
The PD-TaD 62 comprises
HV coupling unit (with integrated measurement impedance)
Is used to couple out high-frequency PD pulses via a measurement
impedance (in accordance with IEC 60270) and convert them into equivalent
voltage signals
PD measuring unit
Is used to record and process the voltage signals from the HV coupling unit
and measure partial discharges
Is used for:
Power supply for all system components
Data transmission between the laptop and PD measurement unit
Is used as VLF voltage source for the measurements
Is used to minimise external influences on the measurement results
PD-TaD 62
822-187-3