Download Print this page

Optex InSight INS-QXI-ST Installation Instructions page 3

Hide thumbs Also See for InSight INS-QXI-ST:

Advertisement

4-5. Walk test
Step
Camera angle settings
5
Camera angle adjustment
1
Loosen the screw to adjust camera angle
Angle can be adjusted with either left or right screw.
Default
Step
System check
6
Check the image at the time of detection on the monitoring portal.
1
Turn LED back ON, if it was turned OFF (
2
Walk around the detection area to make sure it is set as intended.
If necessary, turn LED OFF again.
3
Fix the cover with the cover lock screw included in the housing,
4
after completion as necessary.
NOTE
20°min.
30°
35°max.
Caution
For the walk test, walk at least 1.0 m (3' 3" ) away from the detector.
For confirmation, the LED will light up according to the alarm output for 3 minutes
after the detector cover is installed again in any setting.
Conduct a walk test at least once a year.
Settings on the InSight web
2
If the angle of the camera is adjusted up or down, the detection area display
of the detector on the screen will be different from the actual one.
Adjust the display on the web. See the IP camera manual.
Replace the back cover
3
- 3 -
DIP switch No. 1
, Default ON).
Replace the Back cover by hand.
1
2

Advertisement

loading