Download Print this page

Optex inSight INS-HX-80N Installation Instructions page 2

Camera and pir detector
Hide thumbs Also See for inSight INS-HX-80N:

Advertisement

1-3. Wiring
NOTE
The connector can be fixed inside
the main body with double-sided tape.
DC power cable
12 V DC power for camera and PIR
Step
2
IP address settings
The default network type of InSight is dynamic. If you do not
have a DHCP server, access the following IP address.
Change the InSight network type to Static and set the
IP address;
Initial address: Refer to the label on the InSight
User name: root
Default password: OPTEX
Refer to the "IP Camera Setting Manual"
in more detail.
Step
Detection area settings and walk test
4
4-1. PIR area direction
Remove the Back cover by hand.
1
Pull back
2
Raise up
1
Parallel
4-2. Detection range limit
Upper flap
Plate 1
Lower flap
8-pin I/O cable
Pink
Orange
Yellow
Brown
Green
Purple
Black
Red
PoE LAN cable
Step
IP camera settings
Adjust PIR area direction
2
Horizontal: ±95°
Vertical: 0° to -20°
[ Mounting height ]
3.0 m: 1 click downward (-1.25°)
2.5 m: Default setting (No click)
Caution
Do not use the vertical angle adjustment of
the main unit other than adjusting the
detection area surface to be parallel to the
ground inclination.
Adjusting the detection range
4-3. Switch settings
Plate 2
DIP switch
Flap fix position
indicator
Plate fix position
indicator
PIR sensitivity
selector
Tamper
Alarm
Do not connect to the N/A terminal.
Caution
It can be also used as a back up for POE
Power
Waterproof cap
for LAN connection
Cut the rubber and put the LAN cable into
(a), then (b) will be assembled to (a) tightly.
As a final step, (c) need to be assembled
to (b) without making any space.
Registration InSight to CHeKT portal
3
The default network type of InSight is dynamic. If you have a DHCP server,
it will automatically set the IP address.
1. Setup your CHeKT Dealer Portal:
2. Before getting started with CHeKT, you will need
access to a CHeKT dealer web portal.
Access to this portal allows you to install and manage
the InSight series. If you do not have an account, please
request a dealer account by visiting:
www.chekt.com/registration
Refer to the "https://support.chekt.com" for more detail.
NOTE
It is possible to refer the location of the detection area following procedure.
In this step, do not change the camera tilt angle on InSight web settings.
The display of the detection area helps to set the area.
Details for
4-2. and 4-3
- 2 -
1-4. Assembling
1
Put the main body back on mounting plate.
Caution
Do not pinch the cable when restoring
the PIR detector.
Settings on the InSight web
SETUP -> PIR DETECTOR -> PIR area viewer
4-4. Close the PIR cover
2
CHeKT settings

Advertisement

loading