Maintenance Procedure

Exterior
The casing of the Fog Burst is steel with a powder paint coating. To clean simply disconnect power source and
wash with a cloth and mild soap and warm water.

Troubleshooting

Check gas pressure: Is compressed gas getting to the solenoid valve?
Check that the air line is connected to a suitable air source at the required pressure.
Power to solenoid: Is power getting to the solenoid?
Check that Fog Burst is connected to the Power Fog Industrial/9D power source.
If using DMX: Check that the second DMX channel being used to control the auxiliary output is at a minimum of
50%.
Ensure that DMX address is set to 555.
If using hand held remote; ensure Duration dial is above the 50% mark.
If using show control remote; ensure a good connection between C + 2 on the terminal block.
7