Show Control Operation; Dmx Operation - Ultratec CLF-4455 Operator's Manual

Power fog industrial fog burst
Table of Contents

Advertisement

Show Control Operation

Show control is achieved by connecting a "Dry" or zero voltage contact to the show control terminals. The
Power Fog Industrial 9D requires no power to signal the fog, only one set of contacts that close for the
entire fogging cue.
For Show Control Operation, the DMX Address must be set on 555. Closing the Show Control Remote
terminals with dry contacts, triggers the following machine functions:
C + 1 = Fog On/ Off w/ Variflow
C + 2 = Fog Burst On
C + 3 = Air Option

DMX Operation

1. Attach a DMX signal to the DMX IN 5 pin connector on the rear of the PFI9D.
A terminator may be required on the DMX OUT connector in some applications.
2. Select a valid DMX address on the numerical selectors for the base address of the fogger.
3. 2 consecutive address will be required. Base DMX= fog rate controlled 0-100%, DMX+1=Fog Burst
power on above 50%.
NOTE: A 3rd DMX Channel (DMX+2) = air on above 50%.(If PFI9D is equipped with optional air
option.).
4. The Valid DMX LED is on solid if good DMX signal is present. DMX control overrides hand remotes.
Slow or irregular flashing indicates poor DMX data.
Smoke
OFF/ON
DRY CONTACTS
C 1 2 3
OFF
ON
VARIFLOW
SMOKE
Contacts
Variflow
LED
www.ultratecfx.com