Operating Procedure

LSG Mark II High Pressure using 20 or 50 lb. cylinders

1. Place the G3000 output directly against the foam ring input of the LSG Mark II.
TECH TIP: Proper alignment can be observed by shining a flashlight into the 10" exit of the LSG Mark II and
noting the G3000 output nozzle is centered in the LSG Mark II input.
2. Connect the blue twist lock connector from the LSG Mark II into Custom port on the rear panel of the G3000.
3. Power up the fog machine by turning on the power switch.
NOTE:
NOTE: This delay allows the liquid CO2 to purge the supply hose of CO2 gases ensuring only Liquid is
available for optimum cooling. The recommended formula for calculating delay time is 1 sec. for every
three feet of supply hose.
Detailed G3000 operating instructions located in G3000 Operators Manual
LSG PRE-FOG TIME
0:00 (mm:ss)
DMX Address: 511
Data 0 D+1 0
4. Adjust the remote flow rate to desired fog output level. It is recommended to start at 50% and adjust
accordingly. The maximum recommended flow for the LSG Mark II High is 75%.
5. An LSG Mark II High requires high pressure CO2 bottles. These are normally available in 20 or 50 lb sizes. For
ease of use it is recommended that bottles with liquid siphon tubes be used.
We do NOT recommend inverting the 50 lb. cylinders as they may pose a tipping hazard. Use 50 lb. cylinders
equipped liquid siphon tubes.
6. The second connection to be made is the CO2 supply hose. This is connected to the liquid port of the CO2
supply. Connect two or more cylinders in a series fashion as illustrated below. A fibre washer is necessary to
prevent leaks and are available from your gas supplier.
7. Tighten the CO2 supply fitting snug with appropriate wrench .
6
www.ultratecfx.com
0-255
When connected to an LSG, set the desired
time for the LSG to inject C02 before the
G3000 begins to produce fog.
(0-2 Minutes)
Using the "+" or "-" buttons select the
desired valid DMX address. (0-511)
Data = fog rate controlled 0-100%,
DMX+1=LSG power on above 50%.
0-255
128 - Relay