Local console. The available options are No password, Require Password,
and Disable access.
Note:
6
Local User exclude. Options are to share access with remote, have no
keyboard for the local user, or have a blank screen + keyboard (no local access
except for mouse).
7
Current time (approx). Displays current time and date set on the SLK.
Changes can only be applied through the web control interface. (This setting is
on the Monitor Settings menu on the SLK8 and SLK 1.)
8
Time zone offset (from UTC). Sets the time offset, in minutes, from Greenwich
Mean Time (GMT). A minus sign indicates you are east of the Greenwich
Observatory. (This setting is on the Monitor Settings menu on the
SLK8 and SLK 1.)
9
Clear memory log buffer. Clears the event log in memory.
10 Power Control menu. Opens the Power Control menu when you want to
change the state of a port on an optional third-party power control unit.
Note:
11 Rotate: Delay after last K/M (SLK16 only). Idle time (keyboard and mouse) in
seconds before rotation starts. Default = 0 (disabled).
12 Rotate: Time showing channel (SLK16 only). Duration, in seconds, that each
channel is displayed. Default = 0 (disabled).
13 Reset the power to outlet n. Turns the power state off and then back on for
outlets 1 through 16, regardless of the current power state (same as Cycle
Power).
14 Turn off power to outlet n. Turns the power state off for the selected outlet
(1-16). Requires use of third-party power control.
15 Turn on power to outlet n. Turns the power state on for the selected outlet
(1-16). Requires use of third -party power control.
SecureLinx SLK Remote KVM User Guide
Disable access renders the SLK inaccessible if remote access fails.
Figure 5-20. Local User Control Screen (2 of 2)
This requires configuring a serial port for power control.
Using the OSD Interface to Configure the SLK
5-19