Alert if no video. Enabling this alert causes a notification if no video signal
comes from one of the controlled servers.
Note:
7
Alert if no NumLock toggle. If this is enabled, the SLK simulates the key being
pressed every few seconds. If the NumLock light does not toggle in response
to pressing the NumLock key, the server is assumed to have crashed and this
error condition becomes active. To enable, select Yes. To disable, select No.
8
Alert if text (blue screen). If this server enters text mode, (which can occur if
the attached server is rebooting and displaying boot information or is displaying
the Windows blue screen). To enable, select Yes. To disable, select No.

Second Monitoring Settings Screen

9
Alert if Turtle Mode active. Turtle Mode is activated if too many bad login
attempts occur between successful logins (this setting is dependent upon the
security level selected). To enable, select Yes. To disable, select No.
10 Alert if host power lost. This alert is triggered if an attached server loses
power. Power loss of the server is determined by power loss on the PS/2 ports.
To enable, select Yes. To disable, select No.
11 Alert if my power is reset. If the SLK is reset or powered off for any reason,
this alert is activated when power is restored. This alert might be used in
combination with other controls. To enable, select Yes. To disable, select No.
12 Alert if my Ethernet link down. If the Ethernet signal to the SLK is lost, this
condition is activated. Since the SLK is off the network in this situation, it is only
able to send the alert once connectivity has been restored. However, the event
is logged for future troubleshooting. To enable, select Yes. To disable, select
No.
13 ICMP Ping this address. This address should be an IP address that will be
pinged continuously. This error condition is triggered if more than half the
SecureLinx SLK Remote KVM User Guide
Active screensavers (DPMS) can trigger this notification erroneously.

Figure 5-7. Monitoring Settings Screen (2 of 3)

Using the OSD Interface to Configure the SLK
5-9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SecureLinx SLK Series and is the answer not in the manual?

This manual is also suitable for:

Securelinx slk1Securelinx slk8Securelinx slk16

Table of Contents