1. INTRODUCTION
2. OPERATING
PRINCIPLES
3. CONSTRUCTION
4. INSTALLATION AND
MAINTENANCE
5. PERIODIC &
ACCEPTANCE TESTS
GE Power Management
Courtesy of NationalSwitchgear.com

TABLE OF CONTENTS

1.1
PRODUCT DESCRIPTION........................................................................ 1-1
1.2
ORDER CODES ........................................................................................ 1-2
1.3
APPLICATION ........................................................................................... 1-4
1.4
1.5
TECHNICAL SPECIFICATIONS................................................................ 1-6
1.6
RANGES AND SETTINGS ........................................................................ 1-7
2.1
INPUTS...................................................................................................... 2-1
2.2
EXTERNAL INPUTS.................................................................................. 2-1
2.3
COMMUNICATIONS PORT ...................................................................... 2-1
2.4
MEASUREMENT ....................................................................................... 2-3
2.5
INVERSE TIME UNIT ................................................................................ 2-3
51 INVERSE (5 A RATED RELAYS)...................................................... 2-4
b
BS142 INVERSE (1 A RATED RELAYS) ............................................... 2-4
53 VERY INVERSE ................................................................................ 2-4
77 EXTREMELY INVERSE .................................................................... 2-4
66 INVERSE LONG TIME ...................................................................... 2-4
2.6
INSTANTANEOUS UNIT ......................................................................... 2-10
2.7
CHANGING SETTINGS........................................................................... 2-10
2.8
SETTINGS ............................................................................................... 2-11
PICKUP TOC........................................................................................ 2-11
PICKUP IOC ......................................................................................... 2-11
c
TIME DIAL ............................................................................................ 2-11
CURVE SELECTION............................................................................ 2-11
IOC DELAY........................................................................................... 2-12
COMMUNICATIONS ADDRESS.......................................................... 2-12
OUTPUT CONTACT CONFIGURATION ............................................. 2-12
2.9
DISPLAY AND RESET ............................................................................ 2-13
2.10
SELF-TEST AND ERROR ROUTINES ................................................... 2-14
3.1
DESCRIPTION .......................................................................................... 3-1
3.2
DISPLAYS ................................................................................................. 3-3
3.3
RECEIVING, HANDLING, AND STORAGE .............................................. 3-3
4.1
INSTALLATION ......................................................................................... 4-1
4.2
PERIODIC CHECKS AND ROUTINE MAINTENANCE............................. 4-5
5.1
DESCRIPTION .......................................................................................... 5-1
5.2
VISUAL INSPECTION ............................................................................... 5-1
5.3
INVERSE TIME UNIT ................................................................................ 5-1
PHASE PICKUP CALIBRATION VERIFICATION .................................. 5-1
b
VERIFICATION OF OPERATING TIME................................................. 5-2
c
VERIFICATION OF TIME DIAL .............................................................. 5-2
5.4
INSTANTANEOUS UNIT ........................................................................... 5-3
VERIFICATION OF PICKUP .................................................................. 5-3
VERIFICATION OF OPERATING TIME................................................. 5-3
5.5
GROUND UNIT.......................................................................................... 5-3