Quick Start Guide
6

Product certifications

Rev 3.13
6.1
European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the
Quick Start Guide. The most recent revision of the EC Declaration of
Conformity can be found at Emerson.com/Rosemount.
6.2
Ordinary Location Certification
As standard, the transmitter has been examined and tested to determine
that the design meets the basic electrical, mechanical, and fire protection
requirements by FM Approvals, a nationally recognized test laboratory
(NRTL) as accredited by the Federal Occupational Safety and Health
Administration (OSHA).
6.3
North America
The US National Electrical Code
(CEC) permit the use of Division marked equipment in Zones and Zone
marked equipment in Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information is clearly defined
in the respective codes.
6.4
USA
6.4.1
I5 USA Intrinsically Safe and Nonincendive
Certificate 3011568
Standards FM Class 3600:1998, FM Class 3610:2010, FM Class
Markings
Note
Transmitters marked with Nonincendive CL I, DV 2 can be installed in
Division 2 locations using general Division 2 wiring methods or
Nonincendive Field Wiring (NIFW). See Drawing 00848-4404.
6.4.2
IE USA FISCO
Certificate 3011568
24
3611:2004, FM Class 3810:2005, ANSI/ISA 60079-0:2009,
ANSI/ISA 60079-11:2009, NEMA 250:1991, IEC 60529:2011
IS CL I, DIV 1, GP A, B, C, D; T4(–50 °C ≤ T
DIV 2, GP A, B, C, D; T4A(–50 °C ≤ T
≤ +70 °C) when installed per Rosemount drawing 00848-4404.
®
(NEC) and the Canadian Electrical Code
a
December 2021
≤ +60 °C); NI CL I,
a
≤ +85 °C); T5(–50 °C ≤ T
Rosemount 848T