Connection to a chimney with forced pull, putting in a pull device, letting out the products of
combustion directly into the external environment. The energy supply to the appliance must be
controlled by the system of forced evacuation and must be interrupted if its capacity falls below
the values prescribed by the norms in force. Restarting the gas supply must only be done manually.
 Forced evacuation under hood
In this case, the fume evacuation device of the appliance must be brought to a height of 1.8 m
from floor level, and the outlet section of the evacuation pipes for products of combustion must
be placed inside the base perimeter of the hood. The energy supply to the appliance must be
controlled by the system of forced evacuation and must be interrupted if its capacity falls below
the values prescribed by the norms in force. Restarting the gas supply must only be done manually.
Preliminary operations
Remove the appliance from the packaging, ensure that it is intact and, if in doubt, do not use it but
contact professionally qualified personnel. The packaging materials are compliant with
environmental safety regulations. They can be stored without risk, or else should be disposed of in
accordance with current national regulations, particularly those regarding the nylon bag and the
polystyrene.
After verifying that the appliance is in good conditions, the protective film may be removed. Clean
the external parts of the appliance carefully with warm water and detergent, using a cloth to remove
all remaining residues and then dry it with a soft cloth. If there are still traces of glue, these can be
removed using a suitable solvent (e.g. acetone). Under no circumstances should abrasive substances
be used. After the installation the appliance should be levelled by lowering or raising the adjustable
legs.
Gas Connection
Before connecting the appliance, it is necessary to check that the type of gas available corresponds to
the type of gas the appliance has been set for. In the event that they do not correspond, it is necessary
to proceed as described in the paragraph Functioning with a gas type different from the type provided
for. The connection to the screwed pipe joints, which have a diameter of ½ inch and are situated on
the appliance bottom, may be fixed or mobile by using a fitting quick-coupler. If flexible piping is
used, it has to be made of stainless steel and meet the regulations in force. All the seals on the junction
threads have to be made of materials certified for gas use. In order to ensure a quick interruption of
the gas supply, before setting up each single appliance, it is necessary to install a cut-off cock; the
device has to be placed in an easily accessible position so that it is possible to turn off the gas supply
when the appliance is not used. After completing the connection, the tightness of the cut-off cock has
to be checked by using a leak-finder spray.
Electric connection
Before connecting the appliance, it is necessary to check that the voltage of the available power supply
corresponds to the voltage the appliance has been set for. If they do not correspond, it is necessary to
modify the connection as shown in the electric diagram, if voltage change is provided for. The
junction box is situated behind the control panel of the top and it is made accessible by unscrewing
the screws that fix the panel, removing it and taking out the junction box.
Furthermore, it is necessary to check that the earthing wire is efficient, that the earth conductor on
the connecting side is longer than the other conductors, that the connecting cable has a
wire bunch adequate for the power absorbed by the appliance, and that the connecting
cable is at least type H07 RN-F. It is necessary to run the cable first through the cable
gland. If the supply cord is damaged, it must be replaced by the manufacturer service

INSTALLATION