Timer Models - Image DE 30 Instruction Manual

Tumble dryer
Table of Contents

Advertisement

TROUBLE SHOOTING
18. Condensation on main door glass.
1)
Too long, undersized, or improperly installed duct work.
2)
Dryer connected to common exhaust duct with another dryer and no back draft damper
was installed in customer furnished duct work.
3)
Customer furnished back draft damper in duct work is sticking in partially closed
position.
19. Dryer or scraping noises at basket (tumbler) area.
1)
Check for object caught in basket (tumbler) / wrapper area.
2)
Basket (tumbler) is out of proper alignment.
a.
Check both the vertical and the lateral alignment.
b.
Check gap between the front panel and the basket (tumbler) front, set screws may
have come loose and the basket (tumbler) walked forward or back.
3)
Loose basket (tumbler) tie rod.
4)
Failed basket (tumbler) support.
20. Excessive noise and / or vibration.
1)
Dryer not leveled properly.
2)
Impeller (fan / blower) out of balance.
a.
Excessive lint builds up on impeller (fan / blower).
b.
Failed impeller (fan / blower).
3)
Loose basket (tumbler) tie rod.
4)
Baskets (tumbler) out of adjustment or adjustment bolts (hardware) are loose.
5)
Failed basket (tumbler.) support.
6)
Loose motor mount.
7)
Failed idler and / or tumbler bearings.
8)
V – belts either too tight or too loose.
B. TIMER MODELS
1.
Dryer will not start...both drive and blower motors are not operating (indicator light is
off).
1)
Dryer control circuit fuse is blown.
2)
Open at location.
a.
Service main fuse or circuit breaker.
3)
Failed push to start relay.
4)
Failed door switch and / or circuit.
5)
Failed heat timer.
6)
Failed dual timer relay.
7-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

De 50De 75

Table of Contents