INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and
state codes. In the absence of these codes, installation must conform to applicable American
National Standards: ANSI Z223.1 – LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA
NO.70 – LATEST EDITION (National Electrical Code) or in Canada, the installation must
conform to applicable Canadian Standards: CAN/CGA – B149.1 – M91 (Natural Gas) or
CAN/CGA – BI49.2 – M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas
Plumbing) or Canadian Electrical Code Parts 1 & 2 CSA C22.1 – 1990 or LATEST EDITION (for
Electrical Connections).
A. LOCATION REQUIRMENTS
Before installing the dryer, be sure the location conforms to local codes and ordinances. In
absence of such codes or ordinances location must conform with the National Fuel Gas Code
ANSI Z223.1 – LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA –
B149.1 – M91 (Natural Gas) or CAN/CGA – B149.2 – M91 (L.P. Gas) or LATEST EDITION (for
General Installation and Gas Plumbing).
1.
The dryer must be installed on a sound level floor capable of supporting its weight. It is
recommended that carpeting be removed from the floor area that the dryer is to rest on.
2.
The dryer must not be installed or stored in an area where it will be exposed to water and / or
weather.
3.
This dryer is for use in noncombustible locations.
4.
Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh
Air Supply in Section D).
5.
Clearance provisions must be made from combustible construction as noted in this manual
(refer to Dryer Enclosure Requirements in Section C).
6.
Provisions must be made for adequate clearances for servicing and for operation as noted in
this manual (refer to Dryer Enclosure Requirements in Section C).
7.
Dryer must be exhausted to the outdoors (refer to Exhaust Requirements in Section E).
8.
Dryer must be located in an area where correct exhaust venting can be achieved as noted in
this manual (refer to Exhaust Requirements in Section E).
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be
necessary.