Adjustments; Lubrication - Image DE 30 Instruction Manual

Tumble dryer
Table of Contents

Advertisement

ROUTINE MAINTENANCE
4.
EVERY 6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust duct work system and
from dryers internal exhaust ducting.
Impeller (fan / blower) belts and drive belts should be examined. Cracked and / or seriously
frayed belts should be replaced. Tighten belts when necessary.
WARNING: The accumulation of lint in the exhaust duct work can create a POTENTIAL FIRE
HAZARD.
WARNING: DO NOT obstruct the flow of combustion and ventilation air. Check customer
furnished back draft dampers in exhaust duct work. Inspect and remove any lint
accumulation which can cause damper to bind or stick.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown
of the heat circuit safety switches or thermostats.
NOTE: When cleaning dryer cabinet(s), avoid using harsh abrasives. A product intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 Days after Installation and Every 6 Months Thereafter
Inspect bolts, nuts, screws (bearing set screws), non – permanent gas connections (unions,
shut – off valves, orifices, and grounding connections). Motor and drive belts should be examined.
Cracked or seriously frayed belts should be replaced. Tighten loose V – belts when necessary.
Complete operational check of controls and valves. Complete operational check of all safety
devices (door switch, lint drawer switch, sail switch, burner and hi – limit thermostats).
C. LUBRICATION
1.
Impeller motor (fan / blower) bearings are sealed bearing, NO lubrication is required.
2.
The motor bearings, idler bearings, and main tumbler shaft bearings are permanently
lubricated. NO LUBRICATION IS NECESSARY.