All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without KSB´s express written consent. Subject to technical modification without prior notice.
Page 3
Contents Contents Supplementary Operating Manual ............ 4 General ......................4 Uncooled pump ....................4 Cooled pump ....................4 General assembly drawing ................5 Oil Mist Lubrication 3 of 6...
Page 4
Table 1: Relevant operating manuals Type series Reference numbers of the operating/installation manuals RPHb 1316.8012, 1316.8013 1.2 Uncooled pump 1.2.1 Fitting the oil mist lubrication system 1. Unscrew plugs 916.N3 and 916.N4 from the bearing brackets. 2. Screw in the pipe unions NPT 1/4" (for oil mist inlet) and NPT 1/2" (for oil mist outlet) and connect the oil mist pipework.
Page 5
1 Supplementary Operating Manual 1.4 General assembly drawing Fig. 1: Oil mist lubrication Table 2: List of components Part No. Description 69-10.03 Protective housing 99-6.N1 Semi-finished product (flat steel) 361.01/.02 Bearing end cover 411.70 Joint ring 642.03 Oil level sight glass 916.N1/.N2/.N3 Plug Oil Mist Lubrication...