Safety Prior to handling the machine, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change anything on the product.
Busch. The machine is intended for the placement in a non-potentially explosive environment. The machine is designed for indoor installation, in case of outdoor installation, ask your Busch representative in order to take specific precautions.
Product Description | 2 Optional Accessories 2.4.1 Inlet Filter The inlet filter protects the machine against dust and other solids in the process gas. The inlet filter is available with a paper or polyester cartridge. Instruction Manual MINK MV 0500-0600 B_EN_en 7 | 40...
3 | Transport Transport WARNING Suspended load. Risk of severe injury! ● Do not walk, stand or work under suspended loads. WARNING Lifting the machine using the motor eye bolt. Risk of severe injury! ● Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as shown. ●...
Storage | 4 Storage ● Seal all apertures with adhesive tape or reuse provided caps. If the machine is to be stored for more than 3 months: ● Wrap the machine in a corrosion inhibiting film. ● Store the machine indoors, dry, dust free and if possible in original packaging preferably at temperatures between 0 ...
~1 m ~1 m ~1 m Other values may apply after Busch approval ● Make sure that the environment of the machine is not potentially explosive. ● Make sure that the ambient conditions comply with the Technical Data [➔ 34]. ● Make sure that the environmental conditions comply with the protection class of the motor and the electrical instruments.
Risk of premature failure! Loss of efficiency! ● Only use an oil type which has previously been approved and recommended by Busch. For oil type and oil capacity see Technical Data [➔ 34] and Oil [➔ 35]. Instruction Manual MINK MV 0500-0600 B_EN_en...
● Make sure that the motor of the machine will not be affected by electric or electromagnetic disturbance from the mains; if necessary seek advice from Busch. ● Make sure that the EMC-class of the machine confirms with the requirements of your supply network system, if necessary provide further interference suppression (EMC-Class of the machine see Technical Data [➔ 34]).
Installation | 5 5.4.1 Wiring Diagram Three-Phase Motor NOTICE Incorrect direction of rotation. Risk of damage to the machine! ● Operation in the wrong direction of rotation can destroy the machine in a short time! Prior to start-up, ensure that the machine is operated in the right direction. ●...
Page 14
5 | Installation L1 L2 L3 The leakage current exceeds 3.5 mA. According to EN 61800-5-1 an additional protective earth conductor (PE2) must be provided: ● Connect the additional protective earth conductor (PE2). Use at least the same cross section as for Installation requirement for protection class IP54: The cable and gasket must be secured against shifting.
Commissioning | 6 Commissioning NOTICE Lubricating a dry running machine (compression chamber). Risk of damage to the machine! ● Do not lubricate the compression chamber of the machine with oil or grease. CAUTION During operation the surface of the machine may reach temperatures of more than 70°C. Risk of burns! ●...
6 | Commissioning Variable-Frequency Drive Overview Control unit Key Overview FUNCT Description Move backward in menu; Exit edit Scroll menu up; increase value mode; Reset faults with long press Change control place; Access control Mover cursor left page; Change direction Move cursor right Start button Scroll menu down;...
Page 17
Commissioning | 6 Display Overview Description Status field STOP/RUN Direction Status field READY/NOT READY/FAULT ALARM Control place: PC/I0/KEYPAD/FIELDBUS Location field (Parameter ID number and current menu lacation) Activated group/item Press OK to enter Number of items in the group Instruction Manual MINK MV 0500-0600 B_EN_en 17 | 40...
6 | Commissioning 6.1.1 Overview I/0 Connection * Selectable signals via DIP-Switch between voltage and current 18 | 40 Instruction Manual MINK MV 0500-0600 B_EN_en...
Commissioning | 6 I/O terminal signals for relay and thermistor terminals and connection example. From Relays and thermistor standard I/O Terminal Signal From term. From term. Description Relay output 1 Relay output 2 Thermistor input 6.1.2 DIP-Switch DIP-Switch Description Standard C = Analogue input 1 operates in current mode (2 …...
Page 20
6 | Commissioning DIP-Switch Description Standard C = Analogue input 2 operates in current mode (2 … 20 mA) 0 = Analogue input 2 located in test mode V = Analogue input 2 operates in voltage mode (2 … 10 V) C = Analogue output operates in current mode (2 …...
Commissioning | 6 6.1.3 Speed Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! ● Do not change any other parameter than described below. NOTE: VFD parameter settings for speed control – MV 0500 B - T434216016 –...
6 | Commissioning 6.1.4 Pressure Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! ● Do not change any other parameter than described below. NOTE: VFD parameter settings for pressure control – MV 0500 B - T434215938 –...
Aqua version is able to convey up to 100% saturated water vapour. The conveyance of other vapours than water vapour shall be agreed upon with Busch. ● Make sure that any condensate from the suction side will not enter the non-operating machine.
Risk of premature failure and loss of efficiency! ● Maintenance work must only be executed by qualified personnel. ● Respect the maintenance intervals or ask your Busch representative for service. ● Shut down the machine and lock against inadvertent start up.
5000 operating hours. Other oils may reduce the change interval. Every 6 years ● Have a major overhaul on the machine (contact Busch). Oil Level Inspection ● Shut down the machine. ● When the machine is stopped, wait 1 minute before checking the oil level.
Oil Change NOTICE Use of an inappropriate oil. Risk of premature failure! Loss of efficiency! ● Only use an oil type which has previously been approved and recommended by Busch. Instruction Manual MINK MV 0500-0600 B_EN_en 27 | 40...
Page 28
7 | Maintenance For oil type and oil capacity see Technical Data [➔ 34] and Oil [➔ 35]. The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak and the machine requires repair. 28 | 40 Instruction Manual MINK MV 0500-0600 B_EN_en...
● Decontaminate the machine as much as possible and state the contamination status in a ‘Declaration of Contamination’. Busch will only accept machines that come with a completely filled in and legally binding signed ‘Declaration of Contamination’ (form downloadable from www.buschvacuum.com).
9 | Decommissioning Decommissioning CAUTION Hot surface. Risk of burns! ● Prior to any action requiring touching the machine, let the machine cool down first. ● Shut down the machine and lock against inadvertent start up. ● Disconnect the power supply. ●...
Use of non-Busch genuine spare parts. Risk of premature failure! Loss of efficiency! ● The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty. Spare part Description Part no.
11 | Troubleshooting Troubleshooting DANGER Live wires. Risk of electrical shock. ● Electrical installation work must only be executed by qualified personnel. CAUTION Hot surface. Risk of burns! ● Prior to any action requiring touching the machine, let the machine cool down first. Description Inlet screen Vacuum relief valve...
Page 33
Technical Data [➔ 34]. Oil level too low. ● Top up oil. For the solution of problems not mentioned in the troubleshooting chart contact your Busch representative. Instruction Manual MINK MV 0500-0600 B_EN_en 33 | 40...
Supply network: TN- and TT-network (cannot be used with corner grounded networks) Immunity: EN 61800-3, 1st and 2nd environment Emissions: EN 61800-3, category C2 as standard * In case of higher or lower temperatures, please consult your Busch representative. 34 | 40 Instruction Manual MINK MV 0500-0600 B_EN_en...
Oil | 13 VS 150 VSB 100 ISO-VG Part number 1 L packaging 0831 164 883 0831 168 351 Part number 5 L packaging 0831 164 884 0831 168 352 Remark Standard oil for non- Food applications (H1) demanding applications To know which oil has been filled in the machine, please refer to the nameplate (NP). Instruction Manual MINK MV 0500-0600 B_EN_en 35 | 40...
14 | EU Declaration of Conformity EU Declaration of Conformity This Declaration of Conformity and the CE-markings affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
UK Declaration of Conformity | 15 UK Declaration of Conformity This Declaration of Conformity and the UKCA-markings affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
Page 40