BUSCH MINK MV 0500 B Instruction Manual

BUSCH MINK MV 0500 B Instruction Manual

Claw vacuum pumps
Hide thumbs Also See for MINK MV 0500 B:

Advertisement

Quick Links

Instruction Manual
MINK
Claw Vacuum Pumps
MV 0500 B, MV 0600 B
0870236303/-_en / Original instructions / Modifications reserved
22/06/2021

Advertisement

Table of Contents
loading

Summary of Contents for BUSCH MINK MV 0500 B

  • Page 1 Instruction Manual MINK Claw Vacuum Pumps MV 0500 B, MV 0600 B 0870236303/-_en / Original instructions / Modifications reserved 22/06/2021...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents 1 Safety ............................3 2 Product Description.......................4 2.1 Operating Principle......................6 2.2 Application........................6 2.3 Accessories ........................6 2.3.1 Inlet Filter......................6 2.4 Explanation of ATEX Classification................. 6 3 Transport ..........................8 4 Storage............................8 5 Installation ..........................9 5.1 Installation Conditions .....................
  • Page 3: Safety

    Safety Prior to handling the machine, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change any- thing on the product.
  • Page 4: Product Description

    2 | Product Description Product Description Version: Speed Control OSG ODP Suction connection Oil drain plug Discharge connection Cooling air inlet Oil fill plug (=Venting valve) Cooling air outlet Oil sight glass Variable-frequency drive Eye bolt Nameplate Inlet filter Inlet filter earth connection Motor terminal box 4 / 32 0870236303_MV0500-0600B_EX_-_IM_en_MD...
  • Page 5 Product Description | 2 Version: Pressure Control PSA2 OSG ODP Suction connection Oil drain plug Discharge connection Cooling air inlet Oil fill plug (=Venting valve) Cooling air outlet Oil sight glass Variable-frequency drive Eye bolt Nameplate Inlet filter Inlet filter earth connection PSA2 Pressure transmitter 2 Motor terminal box...
  • Page 6: Operating Principle

    ATEX Classification [► 6]. Conveying of other media leads to an increased thermal and/or mechanical load on the machine and is permissible only after a consultation with Busch. The machine is capable of maintaining ultimate pressure, see Technical Data [► 29]. The machine is suitable for continuous operation.
  • Page 7 IIIB = Dust Group, indicates the machine with the supplied inlet filter (IF) is suitable for dust groups IIIA or IIIB. For dust group IIIC please contact Busch. Group III Electrical equipment for places with an explosive dust atmosphere.
  • Page 8: Transport

    3 | Transport Transport WARNING Suspended load. Risk of severe injury! • Do not walk, stand or work under suspended loads. WARNING Lifting the machine using the motor eye bolt. Risk of severe injury! • Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as shown.
  • Page 9: Installation

    ~1 m ~1 m ~1 m Other values may apply after Busch approval • Make sure that the ambient conditions comply with the Technical Data [► 29]. • Make sure that the environmental conditions comply with the protection class of the motor and the electrical instruments.
  • Page 10: Connecting Lines / Pipes

    5 | Installation If the machine is installed at an altitude greater than 1000 meters above sea level: • Contact your Busch representative, the motor should be derated or the ambient temperature limited. If additional electrical components not included in scope of delivery should be added: •...
  • Page 11: Filling Oil

    Use of an inappropriate oil. Risk of premature failure! Loss of efficiency! • Only use an oil type which has previously been approved and recommended by Busch. For oil type and oil capacity see Technical Data [► 29] and Oil [► 29]. Check oil level The oil level should stay constant over the lifetime of the oil.
  • Page 12: Electrical Connection (For Variable-Frequency Drive)

    • Make sure that the motor of the machine will not be affected by electric or electro- magnetic disturbance from the mains; if necessary seek advice from Busch. • Make sure that the EMC-class of the machine confirms with the requirements of your supply network system, if necessary provide further interference suppression (EMC-Class of the machine see Technical Data [► 29]).
  • Page 13: Wiring Diagram Variable-Frequency Drive

    Installation | 5 5.5.2 Wiring Diagram Variable-Frequency Drive CAUTION The machine can start immediately when power is supplied. Risk of inadvertent start-up! • Make sure that a start-up will not lead to a dangerous situation. L1 L2 L3 The leakage current exceeds 3.5 mA. According to EN 61800-5-1 an additional pro- tective earth conductor (PE2) must be provided: •...
  • Page 14: Commissioning

    6 | Commissioning Commissioning NOTICE Lubricating a dry running machine (compression chamber). Risk of damage to the machine! • Do not lubricate the compression chamber of the machine with oil or grease. CAUTION During operation the surface of the machine may reach temperatures of more than 70°C. Risk of burns! •...
  • Page 15: Variable-Frequency Drive Overview

    Commissioning | 6 6.1 Variable-Frequency Drive Overview ST O P READY Main Menu Quick Setup ( 17 ) Monitor ( 5 ) Parameters ( 12 ) FUNCT Control unit Key Overview Move backward in menu; Change control place Exit edit mode; Access control page Reset faults with long press Scroll menu up;...
  • Page 16 6 | Commissioning Display Overview Status field READY/NOT READY/FAULT Direction ALARM Control place: PC/I0/KEYPAD/FIELDBUS Status field STOP/RUN Location field (Parameter ID number and current menu lacation) Activated group/item Press OK to enter Number of items in the group 16 / 32 0870236303_MV0500-0600B_EX_-_IM_en_MD...
  • Page 17: Overview I/0 Connection

    Commissioning | 6 6.1.1 Overview I/0 Connection * Selectable signals via DIP-Switch between voltage and current 0870236303_MV0500-0600B_EX_-_IM_en_MD 17 / 32...
  • Page 18: Dip-Switch

    6 | Commissioning 6.1.2 DIP-Switch DIP-Switch Description Standard C = Analogue input 1 operates in current mode (2 … 20 mA) 0 = Analogue input 1 located in test mode V = Analogue input 1 operates in voltage mode (2 … 10 V) C = Analogue input 2 operates in current mode (2 …...
  • Page 19: Speed Control

    Commissioning | 6 6.1.3 Speed Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! • Do not change any other parameter than described below. NOTE: VFD parameter settings for speed control – MV 0500 B - T434216016 –...
  • Page 20: Pressure Control

    6 | Commissioning 6.1.4 Pressure Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! • Do not change any other parameter than described below. NOTE: VFD parameter settings for pressure control – MV 0500 B - T434215938 –...
  • Page 21: Conveying Condensable Vapours

    The machine in Aqua version is able to convey up to 100% saturated water vapour. The conveyance of other vapours than water vapour shall be agreed upon with Busch. • Make sure that any condensate from the suction side will not enter the non-operat- ing machine.
  • Page 22: Maintenance

    Risk of injuries! Risk of premature failure and loss of efficiency! • Respect the maintenance intervals or ask your Busch representative for service. • Shut down the machine and lock against inadvertent start up. • Vent the connected lines to atmospheric pressure.
  • Page 23: Oil Level Inspection

    Maintenance | 7 7.2 Oil Level Inspection • Shut down the machine. • When the machine is stopped, wait 1 minute before checking the oil level. The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak and the machine requires repair.
  • Page 24: Oil Change

    Use of an inappropriate oil. Risk of premature failure! Loss of efficiency! • Only use an oil type which has previously been approved and recommended by Busch. Drain pan Cleaning cloth For oil type and oil capacity see Technical Data [► 29] and Oil [► 29].
  • Page 25: Overhaul

    • Decontaminate the machine as much as possible and state the contamination status in a ‘Declaration of Contamination’. Busch will only accept machines that come with a completely filled in and legally bind- ing signed ‘Declaration of Contamination’ (form downloadable from www.buschvacuum.com).
  • Page 26 0482 137 352 Inlet screen 0534 166 184 Inlet filter cartridge Paper 0532 232 522 Inlet filter cartridge Polyester 0532 232 523 If other parts are required: • Contact your Busch representative for the detailed spare parts list. 26 / 32 0870236303_MV0500-0600B_EX_-_IM_en_MD...
  • Page 27: Troubleshooting

    (VRE) is misadjusted or de- lief valve (VRE) fective. The inlet filter cartridge (op- • Replace the inlet filter tional) is partially clogged. cartridge. Internal parts are worn or • Repair the machine (con- damaged. tact Busch). 0870236303_MV0500-0600B_EX_-_IM_en_MD 27 / 32...
  • Page 28 (CPL). Oil level too low. • Top up oil. Defective bearings. • Repair the machine (con- tact Busch). The machine runs too hot. Insufficient cooling. • Remove dust and dirt from the machine. Ambient temperature too • Observe the permitted high.
  • Page 29: Technical Data

    (cannot be used with corner grounded networks) Immunity EN 61800-3, 1st and 2nd environment Emissions EN 61800-3, category C2 as standard * In case of higher or lower temperatures, please consult your Busch representative. 13 Oil VS 150 VSB 100 ISO-VG Part number 1 L packaging...
  • Page 30: Eu Declaration Of Conformity

    14 EU Declaration of Conformity This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer.
  • Page 31 Note...
  • Page 32 Busch Vacuum Solutions We shape vacuum for you. Argentina Denmark Malaysia South Africa info@busch.com.ar info@busch.dk busch@busch.com.my info@busch.co.za Australia Finland Mexico Spain sales@busch.com.au info@busch.fi info@busch.com.mx contacto@buschiberica.es Austria France Netherlands Sweden busch@busch.at busch@busch.fr info@busch.nl info@busch.se Bangladesh Germany New Zealand Switzerland sales@busch.com.bd info@busch.de sales@busch.co.nz...