Summary of Contents for BUSCH MINK MV 0310 B

  • Page 1 MINK Claw Vacuum Pumps MV 0310 B Instruction Manual 0870168572 | A0002_en-US | Original instructions 1/17/2023...
  • Page 2: Table Of Contents

    Table of Contents​ Table of Contents Safety..................................Product Description ............................. Operating Principle ............................. Intended Use ............................... Standard Features............................... 2.3.1 Vacuum Relief Valve..........................2.3.2 Pressure Monitoring..........................Optional Accessories............................2.4.1 Inlet Filter ............................... Transport ................................Storage .................................. Installation ................................Installation Conditions............................Connecting Lines / Pipes ............................ 5.2.1 Suction Connection..........................
  • Page 3: Safety

    Safety Prior to handling the machine, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change anything on the product.
  • Page 4: Product Description

    2 | Product Description​ Product Description Version: Speed Control VSD (optional position) Description Suction connection Discharge connection Oil fill plug (=Venting valve) Oil drain plug Cooling air inlet Cooling air outlet Oil sight glass Non-return valve (integrated) Motor terminal box Variable speed drive Eye bolt Nameplate...
  • Page 5 Product Description​ | 2 Version: Pressure Control PSA1 PSA2 VSD (optional position) Description Suction connection Discharge connection Oil fill plug (=Venting valve) Oil drain plug Cooling air inlet Cooling air outlet Oil sight glass Non-return valve (integrated) Motor terminal box Variable speed drive Eye bolt Nameplate...
  • Page 6: Operating Principle

    Busch. The machine is intended for the placement in a non-potentially explosive environment. The machine is designed for indoor installation, in case of outdoor installation, ask your Busch rep- resentative in order to take specific precautions.
  • Page 7: Standard Features

    Product Description​ | 2 Standard Features 2.3.1 Vacuum Relief Valve The ultimate pressure is limited by a vacuum relief valve (VRE). The vacuum relief valve is adjusted ex-works to the minimum permitted ultimate pressure shown on the nameplate (NP). If the machine operates with a variable speed drive using the pressure control mode, the ultimate pressure is limited electronically by the variable speed drive and the pressure control.
  • Page 8: Transport

    3 | Transport​ Transport WARNING Suspended load. Risk of severe injury! ● Do not walk, stand or work under suspended loads. WARNING Lifting the machine using the motor eye bolt. Risk of severe injury! ● Do not lift the machine using the eye bolt fitted to the motor. Only lift the machine as shown. ●...
  • Page 9: Storage

    Storage​ | 4 Storage ● Seal all apertures with adhesive tape or reuse provided caps. If the machine is to be stored for more than 3 months: ● Wrap the machine in a corrosion inhibiting film. ● Store the machine indoors, dry, dust free and if possible in original packaging preferably at temperatures between 0 ...
  • Page 10: Installation

    ● Make sure that all provided covers, guards, hoods, etc. are mounted. If the machine is installed at an altitude greater than 1000 meters above sea level: ● Contact your Busch representative, the motor should be derated or the ambient temperature limited.
  • Page 11: Connecting Lines / Pipes

    ● Busch recommends the use of the optional horizontal inlet filter and the water separator to col- lect the condensate and prevent it from flowing into the pump.
  • Page 12: Discharge Connection

    Risk of premature failure! Loss of efficiency! ● Only use an oil type which has previously been approved and recommended by Busch. For oil type and oil capacity see Technical Data [➔ 36] and Oil [➔ 37]. The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak and the machine requires repair.
  • Page 13: Electrical Connection

    ● If the machine is equipped with a power connector, install a residual current protective device to protect persons in case of isolation default. ● Busch recommends installing a type B residual protective device suitable for the electrical in- stallation.
  • Page 14: Wiring Diagram Three-Phase Motor

    6 | Electrical Connection​ Wiring Diagram Three-Phase Motor NOTICE Incorrect direction of rotation. Risk of damage to the machine! ● Operation in the wrong direction of rotation can destroy the machine in a short time! Prior to start-up, ensure that the machine is operated in the right direction. ●...
  • Page 15: Wiring Diagram Variable Speed Drive (Vsd)

    Electrical Connection​ | 6 Wiring Diagram Variable Speed Drive (VSD) CAUTION The machine can start immediately when power is supplied. Risk of inadvertent start-up! ● Make sure that a start-up will not lead to a dangerous situation. The leakage current exceeds 3.5 mA (AC). According to EN 61800-5-1 an additional protective earth conductor (PE2) must be provided: ●...
  • Page 16: Commissioning

    7 | Commissioning​ Commissioning NOTICE Lubricating a dry running machine (compression chamber). Risk of damage to the machine! ● Do not lubricate the compression chamber of the machine with oil or grease. CAUTION During operation the surface of the machine may reach temperatures of more than 70°C. Risk of burns! ●...
  • Page 17: Variable Speed Drive Overview

    Commissioning​ | 7 Variable Speed Drive Overview Description Control unit LED display Description Lights when the machine is connected to the power supply. Lights during operation of the machine. Lights when a fault occurs. Lights when the machine is ready for operation and no faults occur. Blinks in case of a warning.
  • Page 18 7 | Commissioning​ Key Overview FUNCT Description Move backward in menu; Exit edit Scroll menu up; increase value mode; Reset faults with long press Change control place; Access control Mover cursor left page; Change direction Move cursor right Start button Scroll menu down;...
  • Page 19 Commissioning​ | 7 Display Overview Description Status field STOP/RUN Direction Status field ALARM READY/NOT READY/FAULT Control place: Location field PC/I0/KEYPAD/FIELDBUS (Parameter ID number and current menu lacation) Activated group/item Number of items in the group Press OK to enter Instruction Manual MINK MV 0310 B_EN_en 19 | 40...
  • Page 20: Overview I/0 Connection

    7 | Commissioning​ 7.1.1 Overview I/0 Connection * Selectable signals via DIP-Switch between voltage and current 20 | 40 Instruction Manual MINK MV 0310 B_EN_en...
  • Page 21 Commissioning​ | 7 I/O terminal signals for relay and thermistor terminals and connection example. From Relays and thermistor standard I/O Terminal Signal From term. From term. Description Relay output 1 Relay output 2 Thermistor input Instruction Manual MINK MV 0310 B_EN_en 21 | 40...
  • Page 22: Dip-Switch

    7 | Commissioning​ 7.1.2 DIP-Switch DIP-Switch Description Standard C = Analog input 1 operates in current mode (2 … 20 mA) 0 = Analog input 1 located in test mode V = Analog input 1 operates in voltage mode (2 … 10 V) C = Analog input 2 operates in current mode (2 …...
  • Page 23: Speed Control

    Commissioning​ | 7 7.1.3 Speed Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! ● Do not change any other parameter than described below. NOTE: VSD parameter settings for speed control T434170442 NOTICE Motor speed exceeds the permitted motor speed range.
  • Page 24: Pressure Control

    7 | Commissioning​ 7.1.4 Pressure Control NOTICE Changing of any other parameters than described below. Risk of damage to the machine! ● Do not change any other parameter than described below. NOTE: VSD parameter settings for pressure control T434212213 Piping and Instrumentation Diagram Process PSA1 process...
  • Page 25 Commissioning​ | 7 Change Values Instruction Manual MINK MV 0310 B_EN_en 25 | 40...
  • Page 26: Conveying Condensable Vapors

    Aqua version is able to convey up to 100% saturated water vapor. The conveyance of other vapors than water vapor shall be agreed upon with Busch. ● Make sure that any condensate from the suction side will not enter the non-operating machine.
  • Page 27: Maintenance

    Risk of injuries! Risk of premature failure and loss of efficiency! ● Maintenance work must only be executed by qualified personnel. ● Respect the maintenance intervals or ask your Busch representative for service. NOTICE Using inappropriate cleaners. Risk of removing safety stickers and protective paint! ●...
  • Page 28: Maintenance Schedule

    5000 operating hours. Other oils may reduce the change interval. Every 6 years ● Have a major overhaul on the machine (contact Busch). Oil Level Inspection ● Shut down the machine. ● When the machine is stopped, wait 1 minute before checking the oil level.
  • Page 29: Cleaning From Dust And Dirt

    Oil Change NOTICE Use of an inappropriate oil. Risk of premature failure! Loss of efficiency! ● Only use an oil type which has previously been approved and recommended by Busch. Instruction Manual MINK MV 0310 B_EN_en 29 | 40...
  • Page 30 8 | Maintenance​ For oil type and oil capacity see Technical Data [➔ 36] and Oil [➔ 37]. The oil level should stay constant over the lifetime of the oil. If the level does fall, this indicates a leak and the machine requires repair. 30 | 40 Instruction Manual MINK MV 0310 B_EN_en...
  • Page 31: Overhaul

    ● Decontaminate the machine as much as possible and state the contamination status in a ‘Dec- laration of Contamination’. Busch will only accept machines that come with a completely filled in and legally binding signed ‘Declaration of Contamination’ (form downloadable from www.buschvacuum.com).
  • Page 32: Decommissioning

    10 | Decommissioning​ Decommissioning DANGER Live wires. Risk of electrical shock. ● Electrical installation work must only be executed by qualified personnel. CAUTION Hot surface. Risk of burns! ● Prior to any action requiring touching the machine, let the machine cool down first. ●...
  • Page 33: Spare Parts

    Use of non-Busch genuine spare parts. Risk of premature failure! Loss of efficiency! ● The exclusive use of Busch genuine spare parts and consumables is recommended for the correct functioning of the machine and to validate the warranty. Spare part Description Part no.
  • Page 34: Troubleshooting

    12 | Troubleshooting​ Troubleshooting DANGER Live wires. Risk of electrical shock. ● Electrical installation work must only be executed by qualified personnel. CAUTION Hot surface. Risk of burns! ● Prior to any action requiring touching the machine, let the machine cool down first. Description Inlet screen Coupling...
  • Page 35 Tech- nical Data [➔ 36]. Oil level too low. ● Top up oil. For resolution of problems not listed in the troubleshooting table, please contact your Busch repre- sentative. Instruction Manual MINK MV 0310 B_EN_en 35 | 40...
  • Page 36: Technical Data

    TN- and TT-network (cannot be used with corner grounded networks) Immunity EN 61800-3, 1st and 2nd environment Emissions EN 61800-3, category C2 as standard * In case of higher or lower temperatures, please consult your Busch representative. 36 | 40 Instruction Manual MINK MV 0310 B_EN_en...
  • Page 37: Oil

    Oil​ | 14 VS 150 VSB 100 ISO-VG Part number 1 L packaging 0831 164 883 0831 168 351 Part number 5 L packaging 0831 164 884 0831 168 352 Remark 1 = Single-phase motor; 2 = Three-phase motor; 3 = Standard oil for non-demanding applications; 4 = Food applications (H1); 5 = Anti-corrosion; 6 = Suitable for continuous operation;...
  • Page 38: Eu Declaration Of Conformity

    EU Declaration of Conformity This Declaration of Conformity and the CE-markings affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Decla- ration of Conformity is issued under the sole responsibility of the manufacturer.
  • Page 39: Uk Declaration Of Conformity

    UK Declaration of Conformity This Declaration of Conformity and the UKCA-markings affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Dec- laration of Conformity is issued under the sole responsibility of the manufacturer.
  • Page 40 With a network of over 60 companies in more than 40 countries and agencies worldwide, Busch has a global presence. In every country, highly competent local personnel delivers custom-tailored support backed by a global network of expertise. Wherever you are.

Table of Contents