C0F32 : Atdc Sensor Un4 Failure; C0F33 : Abnormally Low T/C As Detected By Atdc; Sensor Un4; C0F34 : T/C Recovery Failure As Detected By Atdc - Minolta Di620 Troubleshooting Manual

Hide thumbs Also See for Di620:
Table of Contents

Advertisement

20) C0F32 : ATDC Sensor UN4 Failure

C0F33 : Abnormally Low T/C as Detected by ATDC Sensor UN4
C0F34 : T/C Recovery Failure as Detected by ATDC Sensor UN4
ATDC Sensor UN4
C0F32, C0F33, C0F34
Step
Check Item
1
Are PJ8A and CN23 plugged securely into
PWB-A?
2
Does the voltage across PJ8A-10B on
PWB-A and GND fall within the range of
DC0.2V to DC4.5V during a copy cycle?
Relevant Electrical Parts
Master Board PWB-A
Result
NO
Plug them in securely.
YES
Change PWB-A.
NO
Change UN4 and developer and then run
the F8 and F5 operations, in that order.
T-74
1155C24TAB
Action

Advertisement

Table of Contents
loading