Minolta Di620 Troubleshooting Manual page 46

Hide thumbs Also See for Di620:
Table of Contents

Advertisement

C0049
Step
Check Item
1
Check M19 for operation.
Does the voltage across PJ8A-12A on
PWB-A and GND change from DC0V to
DC24V when the Start key is pressed?
2
Does the voltage across PJ8A-11A on
PWB-A and GND change from DC5V to
DC0V when the Start key is pressed?
C004A
Step
Check Item
1
Check M17 for operation.
Does the voltage across PJ10A-6B on
PWB-A and GND change from DC0V to
DC24V when the malfunction is reset?
2
Does the voltage across PJ10A-4B on
PWB-A and GND change from DC5V to
DC0V when the malfunction is reset?
Result
NO
Change PWB-A.
YES
Change PWB-A.
NO
Check gears for overload and, if they are
okay, change M19.
Result
NO
Change PWB-A.
YES
Change PWB-A.
NO
Check gears for overload and, if they are
okay, change M17.
T-41
Action
Action