Minolta Di620 Troubleshooting Manual page 64

Hide thumbs Also See for Di620:
Table of Contents

Advertisement

C0600
Step
Check Item
1
Is PJ3IC securely plugged into PWB-IC?
2
Check M31 for operation.
Does the voltage across PJ1IC-11 on
PWB-IC and GND change from DC5V to
DC0V when the malfunction is reset?
3
Is the voltage across PJ3IC-6 on PWB-IC
and GND DC5V?
C0602
Step
Check Item
1
Has the cable snapped off, is it unwound or
loose, or does a portion of the cable ride
over another?
2
Is PJ3IC plugged properly into PWB-IC?
3
Check M31 for operation.
Does the voltage across PJ1IC-11 on
PWB-IC and GND change from DC5V to
DC0V when the malfunction is reset?
4
Is the voltage across PJ3IC-6 on PWB-IC
and GND DC5V?
5
Is PJ9IB plugged properly into PWB-IB and
PJ14 into PC55?
6
Does the voltage across PJ9IB-2A on
PWB-IB and GND change to DC0V when
PC55 is blocked?
C0650
Step
Check Item
1
Has the cable snapped off, is it unwound or
loose, or does a portion of the cable ride
over another?
2
Is PJ9IB securely plugged into PWB-IB
and PJ14 into PC55?
3
Is the light blocking plate installed prop-
erly?
4
Does the voltage across PJ9IB-2A on
PWB-IB and GND change to DC0V when
PC55 is unblocked?
Result
NO
Plug it in securely.
NO
Check gears for overload and, if they are
okay, change M31 or PWB-IC.
YES
Change PWB-IB.
NO
Change PWB-IC.
Result
YES
Correct or change the cable.
NO
Plug it in properly.
NO
Check gears and belts for overload and, if
they are okay, change M31 or PWB-IC.
NO
Change PWB-IC.
NO
Plug them in properly.
YES
Change PWB-IB.
NO
Change PC55.
Result
YES
Correct or change the cable.
NO
Plug them in securely.
NO
Reinstall.
YES
Change PWB-IB.
NO
Change PC55.
T-59
Action
Action
Action

Advertisement

Table of Contents
loading

Table of Contents