Figure 18 Installing the processor
CAUTION: To prevent overheating or a possible system crash, use only a heat sink model specified
for the HP ProLiant DL170h Generation 6 server.
To install the heat sink:
Put the heat sink frame on the CPU socket.
1.
Properly align the heat sink mounting pins to the system board mounting holes.
2.
Tighten the mounting pins clockwise to secure the heat sink connection to the system board.
3.
CAUTION: To prevent the heat sink from tilting to one side during installation and removal
procedures, use a diagonally opposite pattern (an "X" pattern) when loosening and tightening the
two spring-loaded screws. Do not over tighten the heat sink's spring-loaded screws to prevent them
from breaking off. A maximum torque of 4 in-Ib is set for the system.
Figure 19 Installing the heat sink
To install the air baffle:
Align the air baffle hooks with the holes on the chassis.
1.
Removal and Replacement Procedures 44