ProDigit Safety symbols The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and the explanations with them, deserve your careful attention and understanding. The symbol warnings DO NOT by themselves eliminate any danger. The instructions and warnings they give are no substitutes for proper accident prevention measures. WARNING: BE SURE to read and understand all safety instructions in this manual, including all safety alert symbols such SYMBOL MEANING bols or pictographs.
ProDigit Safety instructions WARNING: BE SURE to read and understand all instructions in this manual before using this level. Failure to follow all instruc- SAFETY PRECAUTIONS FOR LASERS WARNING: hazardous radiation exposure. WARNING: The use of optical instruments such as, but not limited to, telescopes or transits to view the laser beam will increase eye hazard.
Page 5
ProDigit dangerous. DO NOT place the Digital level in a position that may cause anyone to stare into the laser beam intentionally or uninten- DO NOT use any magnifying optical tools such as, but not limited to, telescopes or transits to view the laser beam. Seri- ALWAYS turn the Digital level off when not in use.
ProDigit This digital level is a highly versatile leveling tool designed for fast, easy operation. Heavy-duty, lightweight aluminum construction, with the LCD digital module constructed of unbreakable ABS polymer that’s sealed against dirt and water, and the toughest acrylic block bubble vials and solid-state laser components all add up to on- age slopes.
Page 7
ProDigit Fig.1a Large, Soft-grip Handles - For ease in carrying, holding level in place. MEASUREMENT FOUNDATION...
Page 8
ProDigit Key function (Fig.1b) Power button -press the button to turn the LCD display screen on. Long press it to turn off the LCD display. REF Button button for about 3 seconds to start the calibration. Sound On/Off Button - Used to activate the beeper. When button is pushed, beeper sounds at level (0°), 45°, M Button - Push to save the current reading in its memory.
Page 9
ProDigit LCD SCREEN ICONS either up or down away from the level (0°). Battery Power Icon - Indicates the amount of battery power in the unit. Replace batteries when the black power bar dis appears. measurements. Indicates that the level is working in relative angle mode. Indicates that the level is wrong positioned or wrong operation in calibration.
Page 10
ProDigit Battery installation (Fig. 2) and the Laser dot. Fig.2 NOTE Open the battery cover, located in the middle of the back of the level (Fig.2). Close the cover securely in place. Turn on the LCD display in centigrade for about 2 seconds, to indicate if level is being used in optimum operating temperature range. The current angle of the level is then displayed, and a picture of that angle is shown either above or below the line for true level.
ProDigit Calibration (Figs.3,4) the beeper will sound for 2 seconds to tell calibrating completed, the LCD will show the current angle in high-accuracy-dis- play. Fig.3 Fig.4 Important NOTE: • The digital level has been pre-calibrated to high-accuracy-display mode. It possibly runs to rough-accuracy-display mode if the temperature changes too much.
ProDigit Measurements Horizontal and Plumb measurements can use both the bubble vial and the LCD readout features. Horizontal measurements (Fig.5) Use the level on horizontal surfaces to true them up. The level’s bubble vials will show when you have the surface level. The bubbles will be exactly in between the marks on the vial.
Page 13
ProDigit Pitch (Fig.7) The digital level can be used to measure the pitch of a roof. It measures the pitch in inches of rise per foot of run. Push the conversion button to change angle to pitch. The if the pitch is above or below the desired measurement. Fig.7 Angle (Fig.8) The digital level measures any angle in degrees with up to 0.1°...
Page 14
ProDigit Laser alignment (Fig.10) This digital level contains a laser diode located inside the left endcap of the level. It provides a bright 635-665 nanometer beam with a useful visibility that extends up to 50m indoors or outdoors (This range is only applicable at night or dark environment.) •...
Page 15
ProDigit Fig.11 Fig.12 • ture, distance and target surface material. ALWAYS use the center point of the dot for your measurement. Rotate the level on the tripod to align chair rail, pictures, etc. 360° around the space. Fig.13 MEASUREMENT FOUNDATION...
Page 16
ProDigit Current reading memorize button and memory recall To save the information of the current reading, press the M button. The level can save nine different readings in its memory. To read out the measurements, press the MR button. The last nine measurements can be read out, beginning with the most recently saved.
ProDigit Turn on the level. The LCD screen indicates the absolute angle between true level and the working surface. Press the REF button to enter relative angle measurement mode. The current angle will be considered to be 0.0° and the display will read 0.0°.
ProDigit Troubleshooting Problem Cause Solution Laser point projection is Batteries are low voltage. Replace with new batteries weak Laser point is not projected •Laser on/off button is not in •Check to make sure the switch ON position. is in On position. •Batteries are installed •Re-install batteries with correct incorrectly.
Page 19
ProDigit • Measurements through glass or plastic windows. • Dirty laser emitting window. • After instrument has been dropped or hit. Please check the accuracy. • other way round) please wait some minutes before carrying out measurements. Electromagnetic acceptability (EMC) •...
ProDigit The instrument is a laser class 2 laser product accortding to DIN IEC 60825-1:2007. It is allowed to use unit without further safety precautions. Warranty This product is warranted by the manufacturer to the original purchaser to be free from defects in material and work- manship under normal use for a period of two (2) years from the date of purchase.
ProDigit Exceptions from responsibility The user of this product is expected to follow the instructions given in operators’ manual. checks of the product’s accuracy and general performance. The manufacturer, or its representatives, assumes no responsibility of results of a faulty or intentional usage or misuse includ- data, loss of data and interruption of business etc., caused by using the product or an unusable product.
Page 22
WARRANTY DOESN’T EXTEND TO FOLLOWING CASES: 1. If the standard or serial product number will be changed, erased, removed or wil be unreadable. 2. Periodic maintenance, repair or changing parts as a result of their normal runout. plication, mentioned in the service instruction, without tentative written agreement of the expert provider. 4.
Page 23
WARRANTY CARD Name and model of the product ________________________________________________ Serial number ________________date of sale_______________________ Name of commercial organization _____________________stamp of commercial organization Warranty period for the instrument explotation is 24 months after the date of original retail purchase. It extends to the During this warranty period the owner of the product has the right for free repair of his instrument in case of manufac- turing defects.
Page 24
__________________________________________________________________________ __________________________________________________________________________ name and model of the instrument Corresponds to ______________________________________________________________ Data of issue _______________________________________________________________ Price Sold ___________________________________ Date of sale ______________________ name of commercial establishment...
Need help?
Do you have a question about the ProDigit 30 and is the answer not in the manual?
Questions and answers