Soft foot

Soft foot measurement can be started from any screen where the 'Soft foot' icon [ 
] is act-
ive. Tap
to start soft foot measurement. The values may be determined by sensor meas-
urement or entered manually from values established using manual methods such as feeler
gauges and shims.
All four foot bolts must be bolted down before starting measurement.

Sensor measurement

Mount the components, enter all required dimensions, and then adjust the laser beam as
required. (You may refer to Mounting components , Dimensions, and Laser beam adjustment.
Activate sensor measurement by swiping the green button
(1)
to "Sensor". The laser beam
must have the status "Laser centered" or "Laser OK".
Tap any one of the four pulsating value fields to start soft foot measurement at the respective
machine foot.
A hint appears to indicate that the shafts should be rotated to position the sensor and reflector
at either the 3:00 or 9:00 o'clock position.