Table of Contents

Advertisement

XY View
The XY View function is used to facilitate the centering of the laser beam on the position
detector before proceeding with measurement.
Tap the shown detector area
l
The XY View screen may be accessed using the menu item "XY View" which appears
l
when the "sensor area"
The XY View screen may be accessed using the menu item "XY View" which appears
l
when the reflector
Displayed are the absolute X,Y coordinates of the laser beam on the position detector, the
angle at which the sensor is currently positioned on the shaft and the sensor serial number.
Center the laser beam dot on the position detector using the adjustment knob and the adjust-
ment thumbwheel. In some cases it may be necessary to move the sensor along the support
posts or sideways by loosening the chain type bracket and slightly rotating it.
The "Set to zero" function may be used to check the effect of environmental and machinery
vibration on the measurement. Note that the "Set to zero" is active only when the laser beam
status [1] is "OK" or "Centered".
SHAFTALIGN touch
(1)
to directly access the XY View screen.
(2)
is tapped.
(3)
is tapped.
On-board help
53

Advertisement

Table of Contents
loading