Display dimming
The period of averaging flow values within the range is set here. Maximum value is 29sec. Averaging
is then used for the other outputs as well.
Display backlight
Here, you can set the period during which the display backlight is turned off after the last activation of
a button. Use the and buttons to select the desired settings from menu (permanent, 40sec, 20sec,
10sec, switched off).
Serial number
The serial number is registered in the factory and cannot be changed by user.
Impulse constant of external sensor
Allows you to set the pulse constant of the external flow sensor.
Empty tube test
Activates and deactivates monitoring of measuring tube filling. If the meter was ordered without the
testing electrode, the flooding test cannot be activated. Two levels of the empty tube test activation are
available for standard conductivity ON(1) and for increased conductivity ON(2).
Technical and installation
manual FLOW 38 Batch (impulse)
Page 19 (total 26)
COMAC CAL s.r.o.