The FPW 05 design is not equipped with the M12 connector but only with a cable entry bushing and three-core PVC cable (cable length is 2 m as standard). Optionally can be also equipped with a M12 connector.
The absolute minimum is typically ten times the amount of inside diameter of the straight pipe before the meter and five times the amount after the meter. FPW Manual Page 4 (total 18) COMAC CAL s.r.o.
Page 5
U, by which means permanent submersion of the lower part with the meter is ensured. For the same reason, we recommend you to place the meter on the upstream side of the ascending piping. FPW Manual Page 5 (total 18) COMAC CAL s.r.o.
(possibly also 4÷20mA current output for FPW 20 version). Since the rotational motion of the paddle wheel depends on flow velocity, the number of output pulses (4÷20mA current output) depends on velocity flow in the place of the paddle wheel and the volume...
Page 9
For version FPW FPW-10 and FPW-20 may K-factors vary depending on the setting of pulse constant meter (dividing ratio). All values of K-factor are valid for water at 25 ° C.
Apply spot welding to two or three locations and check the perpendicularity to the piping axes. If everything is correct, make a weld all round, making sure that the adapter cannot be deformed by welding. FPW Manual Page 10 (total 18) COMAC CAL s.r.o.
Install the drilling device with the adapter on the bored hole in a standard way including sealing O-ring. FPW Manual Page 11 (total 18) COMAC CAL s.r.o.
▪ When blending a mixture of substances (or blending the same substances with different values), it is necessary to incorporate the flow meter either before the blending point or at a sufficient distance after it (min. 50d), otherwise it may cause measurement inaccuracy. FPW Manual Page 12 (total 18) COMAC CAL s.r.o.
VERSION FPW 05 The meter is connected by means of a 3-core PVC cable with standard 2m cable length The optional connection of the M12 connector is as on FPW-10, where the pin 4 TTL output. Standard wiring: Brown PIN1 –...
Pulse output (FPW 05 only) In case of FPW 05 flow meters, it is only the pulse output dependent on the flow velocity within the range of 0.3-6m/sec. User wiring Internal wiring Wiring example: Pulse output or make/break contact (FPW 10 and FPW 20 only)
4-20mA output (FPW 20 only) The manufacturer delivers the meter with output set to 4-20mA in such a manner that at zero flow velocity of the medium, the output value is 4mA and at 6m/sec it is 20mA. The dependence of flow on velocity is linear.
Customization and control of FPW meter In case of FPW 05 version, it is not possible to set or change its parameters that are set by the manufacturer. This version does not have a button. Setting by button is only available in FPW 10 and FPW 20 versions.