Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to
follow Local and NEC electrical codes. To provide safe operation, the SwimPure Plus
must be properly grounded and bonded.
Input Power For stand alone operation:
Wire the SwimPure Plus to the LOAD SIDE of the filter pump timer. It is very important
that the SwimPure Plus is powered only when the pump is running.
Refer to the wiring label on the SwimPure Plus as well as the diagram below to determine
correct wiring connections. The SwimPure Plus is shipped from the factory with the
configuration jumpers in 240VAC position. If using 120VAC, move the jumpers as
shown below. For Canadian models, the SwimPure Plus shall be connected to a circuit
protected by a class A ground fault interrupter. Be sure to connect the ground wire to
the green ground screw terminal located on the bottom of the enclosure.
TYPICAL 240 VAC WIRING
SUBPANEL
GROUND
Note: Wire the pump directly to the timeclock--do not use the SwimPure Plus as a junction box.
Bonding:
A lug used for bonding is attached to the bottom of the SwimPure Plus enclosure (see
diagram below). The SwimPure Plus must be bonded with an 8 AWG copper wire (6
AWG Canada) to the pool bonding system.
Electrolytic Cell and Flow Switch:
The electrolytic cell and flow switch cables are terminated with connectors which plug
into the SwimPure Plus, for easy attachment and removal. The door of the SwimPure
Plus must be open to access the cell cable connector. The flow switch plugs into a
connector (similar to a telephone jack) located outside, on the bottom of the enclosure.
Refer to the diagram below for the location of these connections.
TIMECLOCK
LINE
LOAD
PUMP
Flow switch connector
Bonding lug to
pool bonding system
SWIMPURE
PLUS
GND
PCB
BONDING
LUG
BONDING
LOOP
Cutout for
cell cable
12
120 VAC
SWIMPURE
PLUS
GND
PCB
IMPORTANT:
MOVE JUMPERS
TO POSITIONS SHOWN

Advertisement