Regulatory Compliance
Note
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or only nonhazardous locations.
Note
This equipment is rated as follows- DC Input Voltage: Maximum Operating Range: 9.6V to 32VDC; Nominal:
12/24 VDC.
Note
This product is suitable for use in environmental air space in accordance with Section 300.22.C of the National
Electrical Code and sections 2-128, 12-010(3), and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
You should not install the power supply or power injector in air-handling spaces.
Note
The maximum ambient operating temperature range is –40 to 140°F (–40 to 60°C).

Hazardous Locations Standards and Marking Strings

The following standards were used for the hazardous locations approvals and certifications:
• CSA C22.2 No. 60079-0:19, 4th Ed., Issued 2019-0
• CAN/CSA-C22.2 No. 60079-7:16, 2nd Ed., Issued 2016-10
• CSA C22.2 No. 213-17, 3rd Ed., Rev. 2019-08-26
• EN IEC 60079-0:2018 EN IEC 60079-7: 2015 +A1:2018
• EN IEC 60079-7: 2015 +A1:2018
• UL 121201, 9th Ed., Rev. 2019-08-26
• UL 60079-0 ,7th Ed., Rev. 2020-04-15
• UL 60079-7 5th Ed. Rev. 2017-04-21
The following hazardous locations strings are provided on the router:
• Class 1, Div 2, Groups A B C D
• Class I, Zone 2, AEx ec IIC T4 Gc
• UL 21 ATEX 2512X
• Ex ec IIC T4 Gc
Cisco Catalyst IR1800 Rugged Series Router Hardware Installation Guide

Hazardous Locations Standards and Marking Strings

93