Summary of Contents for Showa Denko Shodex PROTEIN LS-G 4J

  • Page 1 Operation Manual Shodex PROTEIN LS-G 4J Version 190422E Operation Manual Shodex™ PROTEIN™ LS-G 4J Sales Office: Technical Support: Showa Denko Europe GmbH info@shodex.de Shodex Business +49 (0)89 / 93 99 62 37 Konrad-Zuse-Platz 3 81829 Munich Quotes and Orders: Europe, Middle East, Africa, Russia Germany order@shodex.de...
  • Page 2: Important Handling Instructions

    Thank you for purchasing the Shodex product. Shodex PROTEIN LS-G 4J is a guard column for high performance Shodex PROTEIN LW-403 4D column which is designed to be used in gel filtration chromatography for precision separation of proteins and/or enzymes. This guard column can not only protect the analytical column, but also suppress the injection noise* that often occurs when using a light scattering detector.
  • Page 3: Column Installation

    Operation Manual Shodex PROTEIN LS-G 4J Version 190422E Column Installation (1) Connect the column to LC system by following the "flow direction arrow" (->) indicated on the column name tag. Position the guard column in front (before the inlet) of the analytical column.
  • Page 4: Sample Preparation

    Operation Manual Shodex PROTEIN LS-G 4J Version 190422E Eluents (1) The following solvents are usable: Various buffer solutions such as phosphate buffer solution, tris-HCI buffer solution, acetate buffer solution with salts are generally used. Salts to be added include sodium chloride, sodium sulfate and ammonium sulfate.
  • Page 5 Operation Manual Shodex PROTEIN LS-G 4J Version 190422E (1) Removal of ionic substances: Flow about 0.5 M salt solution or phosphate buffer solution of about pH 3.0 through the column as cleaning solvent. (2) Removal of hydrophobic substances: Flow the eluent to which about 10 - 20 % of water-soluble organic solvents such as acetonitrile or methanol is added through the column as cleaning solvent.
  • Page 6 2) Any claim of inconformity to the specification must be notified to Showa Denko K.K. within ten (10) days after delivery to the user. User's exclusive remedy and Showa Denko K.K.'s exclusive liability for such claim are limited to the replacement of the Shodex product in question.
  • Page 7 Operation Manual Shodex PROTEIN LS-G 4J Version 190422E Product Information: Shodex SEC Columns (aqueous GPC) Shodex SEC column series cover the analysis of water-soluble molecules like proteins, enzymes, biomolecules, polysaccharides, surfactants and polymers. They have different target molecular weight ranges and exclusion limits depending on the pore size. Guard columns are available for each series.