Paradyne FrameSaver 9620 User Manual page 65

Hide thumbs Also See for FrameSaver 9620:
Table of Contents

Advertisement

9621-A2-GB20-30
Message
What It Indicates
No DLCIs Available for
A management PVC is
Net Link
being created and the
maximum DLCIs already
exist.
No Management PVC
No management PVCs
have been created.
No Security Records
Delete was selected from
to Delete
the Administer Login
screen, and no security
records had been defined.
Out of Sync
If Monitor Pattern was
selected, it means the test
pattern generator and
receiver have not yet
synchronized. (Path:
main/test/port- n _ phy or
network_ phy)
If Monitor Pattern was
selected, it means that
5 packets out of 25 are
missing or out of sequence.
(Path: main/test/network,
port-1, port-2, or BRI-B1/
pvc)
Password Matching
Password entered in the
Error – Re-enter
Re-enter Password field of
Password
the Administer Logins
screen does not match
what was entered in the
Password field.
August 1997
Maintenance and Troubleshooting
What To Do
Do not create the link.
Delete an existing DLCI, and
try again.
Check that the following have
been defined:
IP address
Subnet mask
Frame relay link
DLCIs
EDLCIs, if the DLCI is
multiplexed
No action needed.
Enter a security record.
No action needed.
Verify that the access unit at
the other end is configured to
Send Pattern.
Correct unit configurations.
Check the line's error rate –
the physical line quality.
Contact service provider.
Try again.
Contact your system
administrator to verify your
password.
5-11

Advertisement

Table of Contents
loading

Table of Contents