Table of Contents

Advertisement

Quick Links

I N S TA L L AT I O N M A N U A L
I N S TA L L AT I O N M A N U A L
A R C H I T E C T S E R I E S
Please leave these instructions behind with the device

Advertisement

Table of Contents
loading

Summary of Contents for Element4 ARCHITECT Series

  • Page 1 I N S TA L L AT I O N M A N U A L I N S TA L L AT I O N M A N U A L A R C H I T E C T S E R I E S Please leave these instructions behind with the device...
  • Page 2 I N S T A L L A T I O N M A N U A L Do not use this product as a primary heat source...
  • Page 3: Table Of Contents

    ELEMENT4 PROCONTROL APP� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �...
  • Page 4 I N S T A L L A T I O N M A N U A L 9�2 CLEANING THE GLASS � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13 9�3 SERVICING THE BURNER �...
  • Page 5: Ce Statement

    This declaration loses its validity when changes to the device are made Do not place any extra decoration material on the burner or in the without the written permission by Element4. You can ask for a copy of combustion chamber. See...
  • Page 6: Warranty

    In case the installer is not able to fix the problem himself, a request can be made to Element4 to do it for him, as long as the service can be done within the borders of the Benelux.
  • Page 7: Remote Control With Full Electronic Ignition

    REMOTE CONTROL WITH FULL ELECTRONIC IGNITION 4�2 IGNITING THE PILOT LIGHT Figure 4.1 The unit is operated using a remote control ( ) or the Element4 Figure 4.3 Check that the control knob (A) is in the ON position( ). Press Figure 4.2...
  • Page 8: Installation Preparation And - Instruction

    The flue system must be constructed from the appliance upwards, with needs no additional ventilation. However an adequate supply of all joints being fully locked and sealed using the Element4 specified fresh air to maintain temperatures and a comfortable environment is parts.
  • Page 9: Fire Safe Installation

    6�3�3 OUTDOOR INSTALLATION resistant plate. This appliance is meant for indoor use. In the case that an Element4 • Never use flammable materials around the fireplace or cove. The appliance is to be installed as part of an indoor outdoor construction,...
  • Page 10 I N S T A L L A T I O N M A N U A L | Chapter 6 a’ Figure 6.1 | Figure 6.4 | Distancer to non-flammable materials (front) Example of isntalation with flue Letter Distances to flammable materials (mm) a - a’...
  • Page 11: Attention Points Flue Gas Extraction

    I N S T A L L A T I O N M A N U A L | Chapter 7 ATTENTION POINTS FLUE GAS EXTRACTION 7�3 BENDS To guarantee the fire safety regarding you flue gas configuration a casing Be aware of the bends in your flue.
  • Page 12: Calculate Flue Length

    For flue configurations that do not function on natural draft, the PowerFan can be used. For extensive installation instructions and the operation of the PowerFan we refer to the manual of the PowerFan on the Element4 website or via your dealer.
  • Page 13: Electrical Circuit

    Android. The app has a user friendly, interactive layout and the design is adjusted for Element4 devices. Up to eight devices can be used with one app, in the situation that multiple fire are installed in the same location. Another functionality of the app is to pre-set the temperature of you device, for a period of one week, to ensure yourself of an optimal desired room temperature.
  • Page 14: Maintenance Instruction

    When you clean your Anti-Reflective glass, make sure you use 9�1�1 (DIS)ASSEMBLY OF THE TRIMS this with the special Element4 cleaner, which is available only via For a tight finish of the fireplace, trims are available. During maintenance Element4. these trims must be removed, before the glass can be removed. The trims •...
  • Page 15 I N S T A L L A T I O N M A N U A L | Chapter 9 Figure 9.2 | Outer window placement method (reverse order for removal) Figure 9.3 | Figure 9.4 | Remove Corner Glass Remove Inner glass brackets...
  • Page 16: 9�3 Servicing The Burner

    9�3�3 THERMOCOUPLES The Element4 fireplaces have two thermocouples; one next to the pilot and one opposite the pilot side of the burner. The completeness and operation of both must be checked. A qualified installer must confirm that both thermocouples are in place and undamaged.
  • Page 17: Decorative (Ceramic) Parts

    I N S T A L L A T I O N M A N U A L | Chapter 10 DECORATIVE (CERAMIC) PARTS This appliance is equipped with a ceramic fire bed with heat-resistant ceramic fibers. Excessive exposure to this material may cause irritation to the eyes, skin and respiratory tract.
  • Page 18: Decoration Instructions

    Where necessary replace damaged components adjustments around the pilot. A single pattern consist of 30 flowers. only with genuine Element4 specified parts. Seal any scrap ceramics in Three times flower 1 (large closed poppy), three times flower 2 (large plastic bags and dispose at proper refuse sites.
  • Page 19: Operating The Fireplace

    I N S T A L L A T I O N M A N U A L | Chapter 11 OPERATING THE FIREPLACE 11�1 BEFORE THE FIRST FIRE Flames and soot During this first fire, examine the flame for appearance and quality. Make sure the cables of the ignition are hanging loosely under the Flames may appear blue at first, but will turn yellow after 15 to 20 device, to ensure a good ignition.
  • Page 20: Atroubleshooter

    I N S T A L L A T I O N M A N U A L | Appendix A TROUBLESHOOTER A�A FIRST AID FOR MALFUNCTION Below you will find an overview of the possible cause and solution in the event of a failure.
  • Page 21 I N S T A L L A T I O N M A N U A L | Appendix A 4,5 mV 4,5 mV Figure A.E | Figure A.A | Figure A.D | Interrupter Bend pin Testpoint Figure A.F | Figure A.B | Wiring receiver Antenna...
  • Page 22 I N S T A L L A T I O N M A N U A L | Appendix A Problem Possible Cause Solution The pilot light goes Insufficient voltage across the thermocouple or Place the measuring pins of the multimeter on the ground and on but goes out too much resistance in the thermocouple circuit black cable of the breaker.
  • Page 23 I N S T A L L A T I O N M A N U A L | Appendix A Figure A.H | Second thermocouple Figure A.L | “Double plus”-button on the remote Figure A.I | Button A on “On” Figure A.J | RESET-button Figure A.M |...
  • Page 24: A�Bnecessary Tools

    If a problem is found, that cannot be solved on site, always contact your Element4 expects are being carried during said services. dealer or directly contact Element4 via our credentials which can be When all these tools are available during service, Element4 guarantees found on the back page of this manual.
  • Page 25: Berrors Codes Procontrol App

    I N S T A L L A T I O N M A N U A L | Appendix B ERRORS CODES PROCONTROL APP B�A MESSAGES SHOWN IN APP Error code Message in App Description Possible cause Contact Service. •...
  • Page 26: B�Bmessages Shown In Remote

    I N S T A L L A T I O N M A N U A L | Appendix B Error code Message in App Description Possible cause Contact Service. • It is not possible to increase flame height •...
  • Page 27: Cfaults And Error Codes In The Remote

    I N S T A L L A T I O N M A N U A L | Appendix C FAULTS AND ERROR CODES IN THE REMOTE Consult this appendix, when error messages occur in the application for smartphone and tablet. C�A F41 ERROR This message will appear if there is no or bad Wi-Fi reception, this can be...
  • Page 28: Dterminal Location

    I N S T A L L A T I O N M A N U A L | Appendix D TERMINAL LOCATION D�B TERMINAL LOCATION WITH HORIZONTAL EXHAUST (C31) D�A TERMINAL LOCATION WITH VERTICAL EXHAUST (C11) Distance Exhaust 1,2 of 3 Position terminal dist.
  • Page 29: Ecalculation Tables Fluegas Restriction

    I N S T A L L A T I O N M A N U A L | Appendix E CALCULATION TABLES FLUEGAS RESTRICTION Attention: For information on how to calcualte bends see CHAPTER 7 CHAPTER 7 In the calcualtion table yo ucan see when you need to place a flue gas restrictor This fireplaces has a minimal start length of 1 meter.
  • Page 30: Ftechnical Data

    I N S T A L L A T I O N M A N U A L | Appendix F TECHNICAL DATA The dataplate specifies for which type of gas, gas pressure and for which country this appliance is intended. The nameplate is attached to a chain. It must remain attached to the chain.
  • Page 31: Gecodesign

    I N S T A L L A T I O N M A N U A L | Appendix G ECODESIGN Since 1 January 2018 every fireplace has been provided with an eco- label which is always supplied with the fireplace. The ecolabel shows which category the fireplace belongs to.
  • Page 32: Hdimensional Drawings

    I N S T A L L A T I O N M A N U A L | Appendix H DIMENSIONAL DRAWINGS On this page you will find the dimensional drawings of the Architect Series with some of the important dimensions that you have to take into account when installing and installing your fireplace.
  • Page 33 Design & Assembly by: E L E M E N T 4 B . V. Info@element4.nl www.element4.nl 2 4 / 0 1 / 2 2 RELEASE DATE |...