23
Turn circuit breakers back ON. Ensure that ringing generator 0 is on circuit
breaker 03-65-01. Ensure that ringing generator 1 is on circuit breaker
03-65-02.
If
the circuit breaker remains switched and the LED
light on the FSP goes out
the circuit breaker trips or the LED light on the FSP
does not go out
24
The next action depends on your reason for performing this procedure.
If you were
directed to this procedure from a maintenance proce-
dure
not directed to this procedure from a maintenance
procedure
25
Return to the maintenance procedure that sent you to this procedure and
continue as directed.
At the MAP terminal
26
Post an LCME in the frame by typing
>POST LCME site frame_no lcme _ no

and pressing the Enter key.

where
site
is the PM location (alphanumeric)
frame_no

is the frame number (00 to 511)

lcme_no
is the number of the LCME unit posted in step 3
27

Wait until there is no system-initiated maintenance on the unit.

28

Return the ManB unit to service by typing

>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number (0 or 1) of the LCME unit
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
in an RSC-S (DS-1) Model B LCME
XPM card replacement procedures
1-985
NT6X30
(continued)
Do
step 24
step 38
Do
step 25
step 26

Hide quick links: