1-636 XPM card replacement procedures
NT3X09
in an RSC-S (DS-1) Model B RMM
Replacing an NT3X09 card in RSC-S RMM
At the MAP
1
2
At the MAP terminal
3
4
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain an NT3X09 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
Set the MAP display to the TTP level and post the trunk by typing
>MAPCI;MTC;TRKS;TTP;POST G MTADRIVER
and pressing the Enter key.
Example of a MAP display:
CM
MS
IOD
Net
.
.
.
TTP
0 Quit
POST
1
2 Post_
TTP
6–009
3 Seize_
CKT TYPE
4
MISC
RMM
5 Bsy_
6 RTS_
7 Tst_
8
9 CktInfo
10 CktLoc
11 Hold
TTP ID IS:
12 Next_
NO CKT, SET IS EMPTY
13 Rls_
TTP:
14 Ckt_
LAST CKTN
15 Trnslvf_
SHORT CLLI IS:
16 Stksdr_
OK, CKT POSTED
17 Pads_
18 Level_
Busy the MTADRIVER by typing
>BSY;BSY;INB;ALL
and pressing the Enter key.
Example of a MAP display:
(continued)
PM
CCS
LNS
.
.
.
DELQ
PM NO. COM LANG
STA
0
16
MATDRIVER
6–009
=
1
MTADRI
Trks
Ext
Appl
.
.
.
BUSYQ
DIG
S
R
DOT TE RESULT
0 IDL
.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents