Replacing an NT6X18 card in an RSC LCM
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or were directed to this procedure by your maintenance
support group.
2
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
At the MAP
3

Post the LEN of the card to be replaced by typing

>MAPCI;MTC;LNS;LTP;POST L SITE lcm_no lsg_no ckt_no

and pressing the Enter key.

where
site
is the site name given to the remote location
lcm_no
is the number of the LCM with the faulty card

lsg_no

is the number of the LSG with the faulty card

ckt_no

is the number of the circuit associated with the faulty card

Example of a MAP display: