Nortel DMS-100 Series Replacement Procedures page 1005

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

and pressing the Enter key.
where
unit_no
is the PM unit number (0 or 1)
Example of a MAP display:
LCME RSCS 14 0 InSv Links
Unit 0:
Unit 1: InSv
Drwr:
01
..
33
The next action depends on how many LCMEs are provisioned in the
equipment frame.
If there
one LCME provisioned in the frame
two LCMEs provisioned in the frame, and you have
not switched RG activity for both LCMEs
two LCMEs provisioned in the frame, and you have
switched RG activity for both LCMEs
34
Repeat steps 28 to 33 for the other LCME provisioned in the equipment
frame.
35
Send any faulty cards for repair according to local procedure.
36
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 39.
37
Consult office personnel to determine why the component is offline. Continue
as directed by office personnel.
38
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
39
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC-S (DS-1) Model A LCME
InSv
/RG:0
/RG:0
23
45
67
89
..
..
..
..
OOS: Cside 0 Pside 0
11
11
11
RG: Pref 0 InSv
01
23
45
Stby 1 InSv
..
..
..
1-973
NT6X30
(end)
Do
step 35
step 34
step 35