7-6 Disks and tape drives
1
2
3
4
5
6

Class 6605

Error string format
6605 node n disk d > Warning
Cause
An attempt is being made to set up a smaller disk as a mirror to a larger
capacity disk.
Action
Call your NT support personnel for assistance

Class 6606

Error string format
6606 node n disk d > Warning
Cause
An attempt is being made to declare two disks as mirrored without
performing a disk synchronization.
Action
Follow the disk synchronization procedure for the disk indicated by the
SEERs. Refer to the DMS VoiceMail Card Replacement Procedures (NTP
297-7001-502) for the appropriate disk pack that is being re-synchronized.

Replacing and resynchronizing disks

If required to either replace or resynchronize disks, refer to the DMS
VoiceMail Card Replacement Procedures (NTP 297-7001-502).
297-7001-503 Standard 02.02 March 1994
Check that the associated SCSI cables are firmly connected.
Reseat the disk pack indicated by the SEER.
Reseat the 68K card associated with the failed disk pack.
Replace the 68K card associated with the failed disk pack.
Replace the disk pack indicated by the SEER.
Replace the 68K transition module associated with the failed disk pack. This
requires re-synchronizing the remaining disk pack to the disk pack indicated
by the SEER.