FLUSHING THE MACHINE
When the machine has reached STANDBY mode, run the following 3 steps:
1. Press 2 Cup button to run water through group head.
2. Run Hot Water for 30 seconds.
3. Activate Steam for 10 seconds.
START UP
• Press the POWER button to switch the machine ON. The POWER
button will flash and the LCD screen will display the current boiler
temperature.
• When the machine has reached operating temperature, the POWER
button light will stop flashing and the MANUAL, 1 CUP and 2 CUP
buttons will illuminate.
• The machine is now in STANDBY mode ready for use.
NOTE
You will not be able to select 1 CUP, 2 CUP or CLEANING CYCLE during
START UP.

LCD INTERFACE

DISPLAY MODES
• 3 modes can be displayed on the LCD screen: Shot Temp, Shot Clock
or Clock.
• Press UP or DOWN arrow to change the display mode between shot
clock & clock. Shot temp will be displayed during an extraction.
1. Shot temp
Displays selected extraction temperature (default set at 93°C), but can
be changed from 86°C - 96°C. See 'Extraction Temperature'.
2. Shot clock
Temporarily displays duration of last espresso extraction in seconds.
3. Clock
Temporarily displays current time (default set at 12.00am if time has
not been set).

GENERAL OPERATION

1 CUP
Press 1 CUP once to extract a single shot of espresso at the
pre-programmed duration (30secs) (see fig. 1 ).
2 CUP
Press 2 CUP button once to extract a double shot of espresso at the
pre-programmed duration (30secs) (see fig. 2 ).
MANUAL
• The MANUAL button allows you to control the espresso pour volume to
suit your preference (see fig. 3 ).
NOTE
To stop an extraction at any time, press the 1 CUP, 2 CUP or MANUAL
button and the machine will return to STANDBY mode.
STEAM
For instant steam, move STEAM LEVER to OPEN position.
The Steam LED will be On (see fig. 4 ).
CAUTION: BURN HAZARD
Pressurised steam can still be released, even after machine has been
switched off. Children must always be supervised.
HOT WATER
Rotate HOT WATER dial to OPEN & CLOSE position to open and close.
The Hot Water LED will be On (see fig. 5 ).
NOTE
You cannot run hot water and extract espresso at the same time.
LCD PROGRAMMING FUNCTIONS
• To program the machine, press MENU button once. The LCD will display
all programming functions. Continue to press MENU button to select your
desired function (see fig. 6 ).
• At any stage during programming, press EXIT to return to STANDBY
mode.
NOTE
The MENU button is disabled when the machine is extracting espresso or
delivering hot water.
SHOT DURATION
1 CUP duration Programming
• Press MENU button until SHOT VOL icon flashes and 1 CUP is
displayed on the LCD screen.
• Press 1 CUP button to start water flow from the group head.
• Press 1 CUP again once required extraction duration has been reached.
• The machine will beep twice to indicate the new 1 CUP duration has
been set.
2 CUP DURATION PROGRAMMING
• Press MENU button until SHOT VOL icon flashes and 2 CUP is
displayed on the LCD screen.
• Press 2 CUP button to start water flow from the group head.
• Press 2 CUP again once required extraction duration has been reached.
• The machine will beep twice to indicate the new 2 CUP duration has
been set.
SHOT VOLUME
1 CUP Volume Programming
• Press MENU button until SHOT VOL icon flashes and 1 CUP is
displayed on the LCD screen.
• Dose & tamp the portafilter with ground coffee. Press 1 CUP button to
start espresso extraction. Press 1 CUP again once desired volume of
espresso has been extracted.
• The machine will beep twice to indicate the new 1 CUP volume has
been set.
2 CUP VOLUME PROGRAMMING
• Press MENU button until SHOT VOL icon flashes and 2 CUP is
displayed on the LCD screen.
• Dose & tamp the portafilter with ground coffee. Press 2 CUP button to
start espresso extraction. Press 2 CUP again once desired volume of
espresso has been extracted.
• The machine will beep twice to indicate the new 2 CUP volume has
been set.
9