CDR500 & CDR700 Repeater Service Manual
Figure 9-5. Radio Configuration,
Accessory Connector, Transmit Radio
12. If the radio is a display model (LCD front
panel), you may enter an "Alias" such as
"Repeater TX".
13. Select a "Channel Bandwidth (kHz):" as
defined by the radio licensing authority.
NOTE
In the United States of America, the
Professional Series radios may not
legally be used as the transmit radio in a
UHF (450 to 512 MHz) repeater or base
station application with 12.5 kHz chan-
nel spacing. The ±2.5-ppm frequency sta-
bility capability of the radio does not
meet the requirements of Part 90 of the
Rules and Regulations of the Federal
Communications Commission (FCC). In
other countries, check local frequency
stability requirements before placing a
Professional Series radio based repeater
or base station in operation.
14. Enter the transmit frequency for the repeater
in the "Rx" area at "Frequency (MHz)".
15. Select the "Squelch Type:" as "CSQ" (Carrier
SQuelch).
16. Enter the transmit frequency for the repeater
in the "Tx" area at "Frequency (MHz)".
17. Select the "Squelch Type:" as "CSQ". Your
screen should appear similar to Figure 9-6.
March, 2001
Programming the Professional Series Radios for use with a ZR310 Repeater Controller
Figure 9-6. Conventional Personality, Basic,
18. Enter any other special programming require-
19. Assign the personality to a zone in the "Per-
20. Program the transmit radio.

Zetron ZR310 Community Repeater Panel

ZR310 Jumper Configurations
Set the internal jumpers of the ZR310 controller accord-
ing to Table 9-1. Refer to the ZR310 service manual,
6880904Z64, for further details.

ZR310 Programming

Refer to the ZR310 service manual, 6880904Z64, for
programming information. The VHF Professional
Series radios require the ZR310 to be programmed for
inverted polarity decode and normal polarity encode.
The UHF Professional Series radios require the ZR310
to be programmed for normal polarity decode and
encode.
6864110R66-O
Transmit Radio
ments in the appropriate windows.
sonality Assignment to Zone" selection win-
dows.
Table 9-1. ZR310 Jumper Settings
Jumper
JP1
JP3
Programming
Setting
B (16)