CDR500 & CDR700 Repeater Service Manual
3. For an externally mounted repeater controller,
locate the blank filler plate and the two P3x8,
Plastite tapping screws, included in kit
HKLN4121.
4. Place the shroud or the blank filler plate in the
upper (controller) opening of the front panel.
5. Use a T10 Torx driver to secure the shroudor
the plate to the front panel with the two P3x8
screws. Tighten to 0.8 N-m (7 in.-lbs.) of
torque.
6. Attach the front panel to the chassis and align
the mounting holes. Ensure that the openings
of the front panel clear the front panels of the
receive and transmit radios and the repeater
controller (if applicable).
7. Using a T15 Torx driver, secure the panel to
the chassis with the four TT 3.5, pan head Tap-
tite screws removed in Step 1, "Removing the
Front Panel" on page 3-3. Tighten to 1.24 N-m
(11 in.-lbs.) torque.
Replacing the Housing Cover to the
CDR700 Chassis
1. Slide the housing cover down onto the chassis
making sure to clear all of the wires from
inside the housing to avoid pinching.
NOTE
The cover only needs a small clearance
from the front panel.
2. Slide the housing cover forward until the lips
engage the front panel.
3. Using a T15 Torx driver, replace the four
TT3.5, pan head Taptite screws removed in
Step 1, "Removing the Housing Cover" on
page 3-2. Tighten to 1.24 N-m (11 in.-lbs.)
torque.

Final Installation

IMPORTANT
To operate the CDR700 repeater, the AC
line cord, antenna feed line, ground
cable, phone lines (not supplied); and
(optional) battery cables must exit from
the rear of the unit.
To operate the CDR700 repeater, you must connect all
of the necessary cables and accessories as follows:
March, 2001
1.
Attach a ground wire from an absolute earth
ground to the 1/4" threaded ground stud on
the left of the repeater housing.
2.
Connect lightning arrestors.
Lightning can damage the CDR700
repeater and its components if the unit
is not grounded properly. For lightning
protection, ground the repeater to an
absolute earth ground using at least #6
gauge copper wire, and use adequate
lightning arrestors.
3.
Connect the antenna lead(s) to the antenna
connector(s) on the back panel of the CDR700
repeater housing.
Before connecting the AC line cord into
an AC mains outlet, ensure that the "115/
230" V ac switch on the power supply is
in the appropriate position. The switch is
accessible from the bottom of the
repeater housing.
4.
Plug the AC line cord into an AC mains outlet.

Repackaging

The CDR700 Repeater Station's shipping box is recom-
mended for reshipping. If it is necessary to repackage
the repeater as a built-up unit, follow these suggested
steps to repackage the unit in its original box.
The CDR700 repeater shipping box may
be used for reshipping a built-up unit.
Please ship with extreme care.
Motorola, Inc. takes no responsibility for
reshipping a built-up CDR700 repeater.
Extreme caution should be taken when
reshipping an CDR700 repeater in its
o r i g i n a l b o x . A b u i l t - u p C D R 7 0 0
repeater could weigh approximately a
maximum of 34 pounds (15.4 kg) when
fully assembled and in its original box.
Lifting improperly can cause injury. Get
help from a second person and use care
when lifting the repeater.
6864110R66-O
CDR700 Desktop Repeater Station
Repackaging
CAUTION
IMPORTANT
CAUTION
CAUTION
CAUTION
3-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdr700