Furuno NX-700A Operator's Manual page 69

Navtex receiver
Hide thumbs Also See for NX-700A:
Table of Contents

Advertisement

FURUNO
4
ANTENNA UNIT
4.1
Antenna type
4.2
Output impedance
4.3
Power supply
5
INTERFACE
5.1
Input data
Output data
5.2
Alarm
6
POWER SUPPLY
6.1 NX-700A
6.2 NX-700B
7
ENVIRONMENTAL CONDITION
7.1
Ambient temperature
Antenna unit
Receiver / Display unit
7.2
Relative humidity
7.3
Waterproofing
Antenna unit
Receiver / Display unit
7.4 Vibration
8
COATING COLOR
8.1
Display unit
8.2
Receiver unit
8.3
Antenna unit
NX-7H: H-field antenna
50 ohms
+7 V to +9 V (thru co-ax cable)
IEC61162-1, -2
GGA, GLL, RMC, ZDA, NRQ, NMK, ACK, GNS, VHW, VTG, VBW
NRX, ALR
PHOTO MOS Contact closure signal (max. 0.5 A, 50 V) for SAR
alert
12-24VDC:
1.5-0.8A
12-24VDC:
0.7-0.4A
-25°C to +70°C
-15°C to +55°C
95% at 40°C (without dew condensation)
IP66
IP20 (NX-700B: IP25 for front panel)
- 2Hz to 5 Hz and up to 13.2 Hz with a deviation of ±1 mm ±10%
(7 m/s2 maximum acceleration at 13.2 Hz);
- above 13.2 Hz and up to 100 Hz with a constant maximum
acceleration of 7 m/s
N3.0
N3.0
N9.5
SP - 2
2
.
NX-700A/B
E5649S01C-M