The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
Clearance:
A: Mantel Height (min.)
B: Sidewall (on one side)
C: Ceiling
(room and/or alcove)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: From Floor
Note:
NOTE: The unit can be installed onto a combustible base.
D
A
G
Regency GF900C-2 Gas Fireplace
Dimension
191mm
Top of Fireplace Opening (Hot Air Outlet)
146mm
Side of Fireplace Opening
1003mm
Top of Fireplace Opening
305mm
420mm Above Fireplace Opening
1480mm
Sidewall to Sidewall (Minimum)
787mm
Front to Back Wall (Maximum)
605mm
Top of Fireplace Opening (Hot Air Outlet)
0
F
B
E
Installed Close
to Floor
F
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Measured From:
No hearth required
E
Alcove
installation
WARNING
Fire hazard is an extreme risk
Flue Clearances to Combustibles
Horizontal - Top
Horizontal - Side
Horizontal - Bottom
Vertical
IMPORTANT: If installing a television above this
appliance, the television must be either fully
recessed into the wall above the fireplace
and or have a mantle below the television. If
the television is left unprotected, the extreme
heat being emitted from this appliance will
result in damage to the television. See clearance
requirements for both mantle and or enclosing
the top of the appliance in this manual.
Installed close
to ceiling.
76mm
51mm
51mm
51mm