maintenance

FAN SERVICE

PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO
ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS
SUPPLY IT TURNED OFF.
1. Remove faceplate, inner frame, glass door, and inner panels - see
instructions in this manual.
2. Remove crystals and stones if installed.
3. Remove burner tray by removing 3 screws shown in Diagram 1.
Diagram 1 - Burner Tray Screw Locations
4. Remove burner by removing 2 screws in locations shown below.
Diagram 2 - Burner Screw Locations
5. Remove air deflector by removing 3 screws in locations shown below.
Diagram 3 - Air Deflector Screw Locations
48
6. Remove 4 screws in locations shown below to remove access
panel. Disconnects at compression fitting on gas valve.
7. Remove valve tray by removing fourteen (14) screws in locations
shown in Diagram 4.
Diagram 4 - Heat Deflector Screws
8. Loosen three (3) screws to remove heat deflector shown in Diagram
5.
Diagram 5 - Valve Tray Screws
9. Remove two (2) screws to remove fan shown in Diagram 6.
Diagram 6 - Fan Screws
10.
Reverse steps to reinstall fan.