3.6.2.6 NCT6106D H/W Monitor

Item
CPU Fan Mode
Fan off temperature
Fan start temperature
Fan full speed
temperature
Fan start PWM
Pwm slope setting
Option
Full on Mode
Automatic Mode[Default],
Manual Mode
10
30
78
100
3
Description
Avalue Smart Fan Mode Select: Mode 01 to Mode
20 Or Manual (No Smart Fan)
Fan will off when temperature lower than this
value
Smart Fan will work when temperature higher
than this value
Fan will full speed when temperature higher than
this value
Fan will stat with this PWM value
PWM SLOPE Selection,0~16