Cab-1011 Cable For Opto-Isolated I/O Connections - Datalogic Matrix 120 Product Reference Manual

Image based reader
Hide thumbs Also See for Matrix 120:
Table of Contents

Advertisement

ALTERNATIVE CONNECTIONS

CAB-1011 CABLE FOR OPTO-ISOLATED I/O CONNECTIONS

The CAB-1011 accessory cable provides opto-isolated input/output signals between the
Matrix 120™ reader and the I/O devices.
PIN
1
9, 13
7, 25
18
19
6
10
8
22
11
12
2
3
4
5
14, 16
15, 17, 20
21, 23, 24
164 MATRIX 120™
Figure 6 - 25-pin D-Sub Male COM, I/O and Power Connector
CAB-1011 CONNECTOR PINOUT
NAME
CHASSIS
Vdc
GND
I1A
I1B
I2A
I2B
O1+
O1-
O2+
O2-
TX+
RX+
TX-
RX-
-
NC
DESCRIPTION
Cable shield connected to chassis
Power Supply Input Voltage +
Power Supply Input Voltage -
External Trigger (polarity insensitive)
External Trigger (polarity insensitive)
Input Signal 2 (polarity insensitive)
Input Signal 2 (polarity insensitive)
Configurable Digital Output 1 - positive pin
Configurable Digital Output 1 - negative pin
Configurable Digital Output 2 - positive pin
Configurable Digital Output 2 - negative pin
Transmitted data (+)
Received data (+)
Transmitted data (-) (RS422 only)
Received data (-) (RS422 only)
Reserved
Not Connected