Manual Calibration

The following examples show some of the typical conditions occurring during the instal-
lation and how they can be tuned manually:

Under-exposure

To correct this result it is recommended to change the following parameters in
their order of appearance:
1. increase the Exposure Time
2. increase the Gain
NOTE
In general, a longer exposure time corresponds to a lighter image but is
susceptible to blurring due to code movement.
High gain settings may produce a grainy image that may affect the
decoding process.
Figure 73 - Example Under Exposure: Too Dark